2—Specifications—Models
48N
(Sizes
NLT018300
thru
NLT036600)
MODEL
48
N
48N
48N
48N
48
N
48N
48
N
48N
48N
SIZE
LT018300
LT024300
HT024300
LT030300
MT030300
HT030300
LT036300
LT036500
LT036600
Unit
Volts—Phase
(60
Hz)
208/230—1
208/230—1
208/230—1
208/230—1
208/230-1
208/230—1
208/230—1
208/230—3
460—3
Operating
Voltage
Range
187—253
187—253
187—253
187—253
187—253
187-253
187—253
187—253
414—506
Unit
Full
Load
Amps
11.5
14.2
14.2
16.8
16.8
17.3
21.2
14.6
7.7
Maximum
Fuse
Size
(Amps)
20
25
25
30
30
30
40
25
15
Minimum
Ampacity
for
Wire
Sizing*
13.6
17.1
17.1
20.4
20.4
20.7
26.9
18.6
9.0
Minimum
Wire
Size
(75
C
Copper)
14
12
12
10
10
10
10
12
14
Maximum
Wire
Length
(Ft.)
60
70
70
100
100
100
75
65
110
Cooling
Capacity
(Btuh)t
17,800
23,800
23,800
29,000
29,000
29,000
35,200
35,200
35,200
Rated
Cooling
Airflow
(cfm)t
600
800
800
1100
1100
1100
1300
1300
1300
External
Static
Pressure
(In.
water)f
0.10
0.10
0.10
0.15
0.15
0.15
0.15
0.15
0.15
ARI
Sound
Rating^
7.8
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
Rated
Heating
Input
(cfm)
40,000
40,000
80,000
60,000
60,000
60,000
Output
Capacity
(Btuh)**
31,000
31,000
Tll»1
61,000
46,000
48,000
48,000
AFUE
(%)**
77.5
77.5
77.5
77.5
77.5
77.5
Rated
Heating
Airflow
(cfm)
658
658
740
658
740
987
987
987
987
Recommended
Minimum
Field-
Supplied
Filter
Size
(Sq
ln.)tt
Disposable-Type
288
384
384
528
624
Cleanable-
or
High-Capacity
Type
192
256
256
352
416
(Applicable
notes
are
listed
below
Table
4.)
Table
3—Specifications—Models
48N
(Sizes
MT036300
thru
VT036600)
MODEL
48N
48N
48
N
48
N
48N
48N
48
N
48
N
48N
SIZE
MT036300
MT036500
MT036600
HT036300
HT036500
HT036600
VT036300
VT036500
VT036600
Unit
Volts—Phase
(60
Hz)
208/230—1
208/230—3
460—3
208/230—1
208/230-3
460—3
208/230—1
208/230—3
460—3
Operating
Voltage
Range
187-253
187—253
414—506
187—253
187—253
414—506
187—253
187—253
414—506
Unit
Full
Load
Amps
21.2
14.6
7.7
22.4
16.8
8.5
22.4
16.8
8.5
Maximum
Fuse
Size
(Amps)
40
25
15
40
25
15
40
25
15
Minimum
Ampacity
for
Wire
Sizing*
26.9
18.6
9,0
26.2
19.3
9.8
26.2
19.3
9.8
Minimum
Wire
Size
(75
C
Copper)
10
12
14
41
12
12
10
10
10
Maximum
Wire
Length
(Ft.)
75
65
110
60
70
70
100
100
100
Cooling
Capacity
(Btuh)f
35,200
35,200
35,200
35,800
35,800
35,800
35,800
35,800
35,800
Rated
Cooling
Airflow
(cfm)f
1300
1300
|
1300
1300
1300
1300
1300
1300
1300
External
Static
Pressure
(In.
water)t
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
ARI
Sound
Rating^
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
Rated
Heating
Input
(cfm)
80,000
80,000
80,00
100,0000
100,000
100,000
120,000
120,000
120,000
Output
Capacity
(Btuh)**
61,000
64,000
64,000
78,000
80,000
80,000
93,000
96,000
96,000
AFUE
(%)**
77.5
77.5
77.5
Rated
Heating
Airflow
(cfm)
987
987
987
1481
1481
1481
1367
1367
1367
Recommended
Minimum
Field-
Supplied
Filter
Size
(Sq
ln.)tt
Disposable-Type
624
624
Cleanable-
or
High-Capacity
Type
416
416
(Applicable
notes
are
listed
below
Table
4.)
Table
4—Specifications—Models
48N
(Sizes
LT042300
thru
HT042600)
MODEL
48N
48
N
48
N
48
N
48N
48
N
48
N
48N
48N
SIZE
LT042300
LT042500
LT042600
MT042300
MT042500
MT042600
HT042300
HT042500
HT042600
Unit
Volts—Phase
(60
Hz)
208/230—1
208/230—1
460—3
208/230—1
208/230—3
460—3
208/230—1
208/230—3
460—3
Operating
Voltage
Range
187—253
187—253
414—506
187—253
187—253
414—506
187—253
187—253
414—506
Unit
Full
Load
Amps
24.6
16.0
8.8
24.6
16.0
8.8
26.7
18.2
9.6
Maximum
Fuse
Size
(Amps)
50
30
15
50
!
30
15
45
30
15
Minimum
Ampacity
for
Wire
Sizing*
31.1
20.4
10.3
31.1
2.4
10.3
31.7
21.1
11.1
Minimum
Wire
Size
(75
C
Copper)
8
10
14
8
10
14
10
12
14
Maximum
Wire
Length
(Ft.)
95
100
100
95
100
100
75
65
110
Cooling
Capacity
(Btuh)t
41,500
41,500
41,500
41,500
41,500
41,500
41,500
41,500
41,500
Rated
Cooling
Airflow
(cfm)t
1500
1500
1500
1500
1500
1500
1500
1500
1500
External
Static
Pressure
(In.
water)f
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
ARI
Sound
Ratingi
7.8
8.0
8.0
8.0
8.0
8.0
8.2
8.2
8.2
Rated
Heating
Input
(cfm)
60,000
60,000
60,00
80,000
80,000
80,000
100,000
100,000
100,000
Output
Capacity
(Btuh)**
46,000
48,000
48,000
61,000
64,000
64,000
78,000
80,000
80,000
AFUE
(%)**
77.5
77.5
-
__
77.5
Rated
Heating
Airflow
(cfm)
987
987
987
987
987
987
1481
1481
1481
Recommended
Minimum
Field-
Supplied
Filter
Size
(Sq
ln.)tt
Disposable-Type
720
720
Cleanable-
or
High-Capacity
Type
480
480
*|f
other
than
75
C
copper
wire
is
used,
determine
size
from
unit
ampacity
and
the
National
Electrical
Code.
Voltage
drop
of
wire
must
be
less
than
2%
of
unit
rated
voltage.
fRated
in
accordance
with
U.S.
Government
D.O.E.
test
procedures
and/or
ARI
Standard
210.
tRated
in
accordance
with
ARI
Standard
270.
**The
capacity
ratings
of
single-phase
units
are
in
accordance
with
U.S.
Government
D.O.E.
test
procedures
and/or
A.G.A.
certification
requirements.
For
3-phase
units,
the
efficiency
rating
is
a
product
thermal
efficiency
rating
determined
under
continuous
operating
conditions,
independent
of
any
installed
system.
tf
Required
filter
areas
shown
are
based
on
the
larger
of
the
ARI-rated
cooling
airflow
or
the
heating
airflow
at
a
velocity
of
300
ft/min
for
disposable
type
or
450
ft/min
for
high-capacity
type.
Air
filter
pressure
drop
must
not
exceed
0.08
in.-water.
7