Air-Cooled Liquid Chillers
Nominal cooling capacity 163-760 kW
50 Hz
Installation, operation and maintenance instructions


Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Carrier AquaSnap 30RB 432 and is the answer not in the manual?

Carrier AquaSnap 30RB 432 Specifications

General IconGeneral
BrandCarrier
ModelAquaSnap 30RB 432
CategoryChiller
LanguageEnglish

Summary

1 - INTRODUCTION

1.2 - Installation safety considerations

Crucial safety guidelines for unit installation, handling, and protection devices.

1.4 - Maintenance safety considerations

Safety protocols for personnel performing maintenance on refrigeration and electrical components.

1.5 - Repair safety considerations

Safety precautions and procedures for unit repair, including refrigerant handling and electrical safety.

2 - MOVING AND SITING THE UNIT

2.2 - Siting the unit

Recommendations for choosing an appropriate installation location, considering access and environmental factors.

2.3 - Checks before system start-up

Comprehensive checklist for verifying installation integrity before initial system operation.

5 - ELECTRICAL DATA - 30RB

5.1 - 162-262 "B" standard (units and units with option 280) and 30RB 302-802 units

Electrical data for standard 162-262 "B" units and 302-802 series.

5.2 - Short-circuit stability current

Information on short-circuit stability current for various unit configurations.

6 - APPLICATION DATA

6.1 - Unit operating range

Defines the operational limits of the unit concerning water and ambient temperatures.

6.2 - Minimum chilled water flow (units without hydronic module)

Specifies the minimum required chilled water flow rate for units without a hydronic module.

6.3 - Maximum chilled water flow (units without hydronic module)

Specifies the maximum allowed chilled water flow rate for units without a hydronic module.

7 - ELECTRICAL CONNECTION

7.1 - Power supply

Requirements for the unit's power supply, including voltage and phase considerations.

7.2 - Voltage phase imbalance (%)

Details on calculating and acceptable limits for voltage phase imbalance.

8 - WATER CONNECTIONS

8.1 - Operating precautions and recommendations

Key precautions and recommendations for connecting and operating water circuits.

8.2 - Hydronic connections

Diagrams and details for connecting units equipped with optional hydronic modules.

8.4 - Frost protection

Methods and options for protecting the unit's hydronic circuits from freezing.

8.5 - Operation of two units in master/slave mode

Instructions for configuring and operating two units in a master/slave setup.

9 - NOMINAL SYSTEM WATER FLOW CONTROL

9.1 - Water flow control procedure

Step-by-step guide for adjusting and controlling water flow rates using balancing valves.

10 - MAJOR SYSTEM COMPONENTS

10.1 - Compressors

Description of hermetic scroll compressors, their features, and safety devices.

12 - STANDARD MAINTENANCE

12.1 - Level 1 maintenance (see note opposite)

Basic maintenance tasks that can be performed by the user for optimal unit performance.

12.2 - Level 2 maintenance (see note opposite)

More advanced maintenance procedures requiring specialized skills, often performed by technicians.

12.3 - Level 3 (or higher) maintenance (see note below)

Highly specialized maintenance operations reserved for manufacturers or authorized agents.

13 - START-UP CHECKLIST FOR 30RB LIQUID CHILLERS (USE FOR JOB FILE)