Do you have a question about the Carrier AQUASnap 30RB and is the answer not in the manual?
Compressor Type | Scroll |
---|---|
Refrigerant | R-410A |
Power Supply | 460V/3Ph/60Hz |
Dimensions (L x W x H) | Varies by model |
Weight | Varies by model, refer to product brochure |
Heating Capacity | Not applicable (Cooling only chiller) |
Sound Pressure Level | Varies by model, refer to product brochure |
Operating Range (Heating) | Not applicable (Cooling only chiller) |
Sound Performance | Low noise design with options for further sound attenuation |
Energy Efficiency | High efficiency scroll compressors, electronic expansion valves, and smart controls |
Physical specifications including sound levels, dimensions, weight, and refrigerant.
Physical specifications for 30RBP units, including sound, dimensions, weight, and refrigerant.
Physical specifications for 30RQ units, including sound, dimensions, weight, and refrigerant.
Physical specifications for 30RQP units, including sound, dimensions, weight, and refrigerant.
Electrical data for 30RB units, including power, current, and start-up current.
Electrical data for 30RBP units, including power, current, and start-up current.
Electrical data for 30RQ units, including power, current, and start-up current.
Electrical data for 30RQP units, including power, current, and start-up current.
Provides short-circuit withstand current ratings and associated protection for TN systems.
Electrical data for factory-installed pumps in hydraulic modules, including efficiency and power.
Specifies power supply requirements, voltage range, and warnings for incorrect supply.
Explains how to calculate voltage phase imbalance and acceptable limits.
Provides guidelines for selecting power supply cable sections based on current and voltage drop.
Defines the operating temperature and pressure ranges for cooling and heating modes.
Provides minimum and maximum water flow rates for various units and hydraulic modules.
Graphical representation of pressure drop versus water flow rate for heat exchangers.
Precautions and recommendations for hydraulic circuit connections and water treatment.
Provides guidelines for protecting the unit and hydraulic circuit from frost damage.
Describes pressure differential control for variable speed pumps and hydraulic circuit cleaning.
Details temperature differential control for variable speed pumps and setpoint adjustment.
Presents static system pressure curves for units with variable speed pumps.
Static system pressure curves for 30RQ/30RQP units, covering high pressure pumps.
Pre-start-up checks covering the entire system, refrigerant, and documentation.
Procedures and precautions for commissioning the unit, including checks on connected equipment.
Critical checks for compressors, hydraulics, and refrigerant charge before start-up.
Describes the hermetic scroll compressors, their features, and safety devices.
Describes fan motor assemblies, their specifications, and compliance with ecodesign regulations.
Illustrates the fan arrangement and circuit connections for various unit models.
Describes the features and characteristics of the SmartVuTM control interface.
Advanced maintenance tasks requiring specialized skills, tools, and manufacturer authorization.
Checks for chilled water pump, oil level, leaks, and voltage imbalance before starting.
Procedure for checking pressure drop and determining flow rate using curves.
Steps to perform the QUICK TEST function and log user menu configuration.