Table 4 — Electrical Data — 50AJ,AK,AW,AY Units (cont)
See Legend and Notes on page 19.
UNIT
SIZE
50A
VOLTAGE
3 PH,
60 Hz
VOLTAGE
RANGE
COMPRESSOR
CONDENSER
FAN MOTOR
EVAPORATOR
FAN MOTOR
POWER
EXHAUST
OPTIONAL
ELECTRIC HEAT
POWER
SUPPLY
Cir A, No. 1 Cir A, No. 2 Cir B, No. 1 Cir B, No. 2
Min Max FLA LRA RLA LRA RLA LRA RLA LRA Qty FLA Hp FLA
FLA
(total)
FLA kW MCA MOCP*
040
208 187 229 25.6 190 25.6 190 34.3 265 34.3 265 4
6.5
(ea)
15 46.2
—
——203.6 225
75.1 27 203.6 225
150.1 54 207.9 250
23.6
——227.2 250
75.1 27 227.2 250
150.1 54 237.4 250
20 59.4
—
——220.1 250
75.1 27 220.1 250
150.1 54 224.4 250
23.6
——243.7 300
75.1 27 243.7 300
150.1 54 253.9 300
25 74.8
—
——239.3 300
75.1 27 239.3 300
150.1 54 243.6 300
23.6
——262.9 300
75.1 27 262.9 300
150.1 54 273.1 300
230 207 253 25.6 190 25.6 190 34.3 265 34.3 265 4
6.6
(ea)
15 42.0
—
——198.7 225
86.6 36 198.7 225
173.2 72 225.7 250
23.6
——222.3 250
86.6 36 222.3 250
173.2 72 255.2 300
20 54.0
—
——213.7 250
86.6 36 213.7 250
173.2 72 240.7 250
23.6
——237.3 250
86.6 36 237.3 250
173.2 72 270.2 300
25 68.0
—
——231.2 250
86.6 36 231.2 250
173.2 72 258.2 300
23.6
——254.8 300
86.6 36 254.8 300
173.2 72 287.7 300
460 414 508 13.5 95 13.5 95 16 120 16 120 4
3.3
(ea)
15 21.0
—
——98.5 110
43.3 36 98.5 110
86.6 72 112.9 125
12.6
——111.1 125
43.3 36 111.1 125
86.6 72 128.6 150
20 27.0
—
——106.0 125
43.3 36 106.0 125
86.6 72 120.4 125
12.6
——118.6 125
43.3 36 118.6 125
86.6 72 136.1 150
25 34.0
—
——114.7 125
43.3 36 114.7 125
86.6 72 129.1 150
12.6
——127.3 150
43.3 36 127.3 150
86.6 72 144.9 175
575 518 632 10.2 75 10.2 75 12.9 80 12.9 80 4
2.6
(ea)
15 17.0
—
——77.9 90
34.6 36 77.9 90
69.3 72 90.6 100
12.6
——90.5 100
34.6 36 90.5 100
69.3 72 106.3 110
20 22.0
—
——84.1 100
34.6 36 84.1 100
69.3 72 96.8 110
12.6
——96.7 110
34.6 36 96.7 110
69.3 72 112.6 125
25 27.0
—
——90.4 110
34.6 36 90.4 110
69.3 72 103.1 125
12.6
——103.0 125
34.6 36 103.0 125
69.3 72 118.8 125