EasyManua.ls Logo

Carrier 50KQA - Deluxe D Controller Wiring

Carrier 50KQA
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
L2
L1
1
PB
2
SEE
NOTE 4
CR
Ground
CB
Use copper
Connection
Refer to Data Plate
Cord
Optional
conductors only.
Power Supply
BLK
NOTE 3
(115V)
WHT
RED
BRN
(265V)
(208V)
230V
ORG
1
BRN
CR
0
YEL
Neutral on 265V Systems
Ground
L2 (ribbed)
L1 (plain)
Trans
SEE
CAP
GRY
F
C
H
YEL
BRN
RED
BLK
2
6
RVS
Not Used
ORG
RED
LOC
BRN
VIO
BRN
VIO
GRY
GRY
RED
BLU
RED
FP2
FP1
HP
BLK
NOTE 4
SEE
Compressor
B (HIGH)
A (LOW)
BM
1
2
BLU
BLK
RED
4
8
R
S
C
YEL
BRN
WV
YEL
YEL
RED
RED
PBS
YEL
GRY
1A
1
BRN
ORG
DM
ORG
PBS
RED
2
3
YEL
ORG
3A
2A
1
2
1B
UMT
RED
RED
WHT
NLL
RED
WHT
UMT
Deluxe
D
Cap
PBS
OS
Transformer
Ground
PB
CR
3
OS
YEL
BLU
6A
6
PBS
5A5
7
7A
GRY
RED
CLOSED=UNOCCUPIED
TIME CLOCK
GRY
GRY
GRY
RED
RED
See Note 2
Refer to Disconnect
power supply connection
box for optional
GRY
YEL
BRN
SEE
NOTE 7
RELAY
FAN ENABLE
FAN
RELAY
SPEED
NO
COM
COM
1
3
5
4
2
HP
NO
LOC
6
8
7
10
9
Y
TEST
R
RV
FP2
RV
FP1
G
NC
P7
24V
EH2
EH1
DC
CCG
CC
RELAY
COMPR
P6
12
CO
C
S
S
COM1
R
C
R
1
3
4
2
COM2
C
TEST
SEE
NOTE 6
7
6
8
ALARM
RELAY
AL2 DRY
5
Y1
Y2
C
R
G
P1
O/W2
W1
P2
AL1
R
C
NSB
AL2
OVR
ESD
FP1
JW3
FP2
LP
JW2
JW1
Low
Low
N.O.
ON
3
2
1
OFF
5
7
6
4
ACC1
3
2
1
OFF ON
5
7
6
4
ACC2
RELAY
RELAY
Not Used
UPM: Disable/Enable
RV on B/RV on O
Unit Stage: 2/1
Dehumid/Normal
T'stat: Heat Cool/Heat Pump
Boilerless: Enable/Disable
PACKAGE
DIP SWITCH
S2
S1
PACKAGE
DIP SWITCH
8
Boilerless: 40°F/50°F
8
R
P3
NO1
A
NO2
NC2
COM
R
COM
NC1
PINS
H
D
Microprocessor
STATUS
FAULT
RELAY
ACC1
Functions
Functions
Not Used
ACC2
Control Logic
H: hi fan/dehumid
JW4
----------
Field Line Voltage Wiring
Field Low-Voltage Wiring
Printed Circuit Trace
Optional Low Voltage
Wiring
Relay Contactor Coil
Solenoid Coil
Thermistor
Ground
Mate-N-Lock
>
>
NOTES:
1. Compressor and Blower Motor thermally protected
internally.
2. All wiring to the unit must comply with NEC and local
codes.
3. Transformer is wired to 115V (WHT) lead for 115/1/60
units, 265V (BRN) Lead for 265/1/60 units or 208V
(RED) Lead for 208/1/60. For 230/1/60 switch RED
and ORG Leads at L1 and insulate RED lead. Trans-
former is energy limiting or may have circuit breaker.
4. FP1 Thermistor provides freeze protection for
WATER. When using ANTI-FREEZE solutions, cut
JW3 jumper.
5. Typical unit-mounted thermostat wiring shown.
6. 24 V Alarm Signal shown. For Dry Alarm Contact, cut
AL2DRY (JW4) Jumper and Dry Contact will be avail-
able between AL1 and AL2.
7. Transformer secondary ground via Deluxe D board
standoffs and screws to Control Box. (Ground avail-
able from top two standoffs as shown.)
PUSH BUTTON SWITCH ATTRIBUTES
X = CLOSED O = OPEN
TERMINALS
1 2345678
1A 1B 2A 3A 4A 5A 6A 7A 8A
STOP
XOOOOOOOO
FAN ONLY
XOOOOXOOO
LOW COOL
OX XOOOXOO
HIGH COOL
OX XOOOOXO
LOW HEAT
XOOXXOXOO
HIGH HEAT
XOOXXOOXX
BLOWER MOTOR WIRING
UNIT SIZE POLE A POLE B
007 5 3
009 5 3
012 5 4
015 4 3
019 4 3
MANUAL CHANGEOVER WITH DELUXE D CONTROLLER
AL
Alarm Relay Contacts
BM
Blower Motor
Cap
Capacitor
CB
Circuit Breaker
CO
Condensate Overflow
CR
Compressor Relay
DM
Damper Motor
FP1
Sensor, Water Coil Freeze Protection
FP2
Sensor, Air Coil Freeze Protection
HP
High-Pressure Switch
LOC
Loss of Charge Pressure Switch
NLL
Night Low Limit Thermostat
OS
Override Switch
PB
Power Terminal Block
PBS
Push Button Switch
RVS
Reversing Valve Solenoid
Trans
Transformer
UMT
Unit Mounted Thermostat
UPM
Unit Performance Monitor
WV
Water Valve
LEGEND

Related product manuals