Summary

SAFETY CONSIDERATIONS

INSTALLATION

Step 1 Check Equipment and Jobsite

Unpacking, inspecting the unit, and verifying jobsite requirements before installation.

Step 2 Connect Supply Ductwork

Instructions for connecting the supply air ductwork to the unit's flange.

Step 3 Make Piping Connections

Steps for connecting water supply and return lines, including balancing valves.

Step 4 Make Electrical Connections

Guide for making field electrical connections, branch circuit disconnect, and ground lead.

Install Balancing Valves

How to install shutoff valves in water lines for adjustment and servicing.

Make Condensate Drain Line Connection

Instructions for connecting the condensate drain line, including trap installation.

START-UP

Water Flow and Temperature Data

Guidelines for water flow rates, entering water temperature, and system cleanliness.

To Start Unit

Steps to follow to safely start the unit after installation, including thermostat adjustment.

Unit Controls and Safety Devices

Overview of safety devices like high-pressure relief valve and overload protection.

SERVICE

Refrigerant Charging

Procedures for checking and adjusting refrigerant charge using charts and devices.

FREEZE-UP PROTECTION

Explanation of controls that prevent unit operation when water approaches freezing.

CHARGEMASTER DEVICE OPERATION

Compressor Removal

Steps for removing a compressor, including safety precautions and refrigerant handling.

MAINTENANCE AND SERVICE PROCEDURES

Lubrication

Information on compressor oil and fan motor bearing lubrication requirements.

Cleaning Coil and Condensate Pan

Maintenance steps for cleaning the unit's coil, condensate pan, and drain.

Indoor Blower Assembly Removal

Procedures for removing the indoor blower assembly for 50VQ and 50HQ models.

Indoor Fan and Motor Removal

Procedures for removing the indoor fan and motor from the unit.

Air Filter and Heat Exchanger Maintenance

Guidance on replacing the return air filter and cleaning the heat exchanger.

TROUBLESHOOTING CHART

ENTIRE UNIT DOES NOT RUN

Troubleshooting steps for when the entire unit fails to operate.

BLOWER OPERATES BUT COMPRESSOR DOES NOT

Diagnosing issues when the blower runs but the compressor does not.

UNIT OFF ON LOW WATER TEMPERATURE CONTROL

Troubleshooting when the unit shuts off due to low water temperature.

UNIT SHORT CYCLES

Identifying causes and solutions for the unit cycling on and off too frequently.

TROUBLESHOOTING CHART (cont)

INSUFFICIENT COOLING OR HEATING

Addressing problems related to inadequate cooling or heating performance.

NOISY OPERATION

Diagnosing and resolving various sources of noise from the unit.