Power W_dng
-- ControlW_dng
_ Condenser A_rflow
_* Evaporat or Airflow
Fig. 6 - Typical Installation
A08207
UNIT SIZE
NOMINAL CAPACITY (ton)
SHIPPING WEIGHT (Ib)
(kg)
COMPRESSOR TYPE
REFRIGERANT
REFRIGERANT QUANTITY (Ib)
QUANTITY (kg)
METERING DEVICE ID
ORIFICE OD (in.)
(mm)
OUTDOOR COIL
ROWS...FINS/in.
FACE AREA (sq. ft)
OUTDOOR FAN
NOMINAL AIRFLOW (cfm)
DIAMETER (in.)
DIAMETER (mm)
MOTOR HP (RPM)
INDOOR COIL
ROWS...FINS/in.
FACE AREA (sq. ft)
INDOOR BLOWER
NOMINAL COOLING AIRFLOW
(cfm)
SIZE L x D (in.)
(mm)
MOTOR (HP)
HIGH-PRESSURE SWITCH (psig)
CUTOUT
RESET (AUTO)
RETURN-AIR FILTERS
THROWAWAY (in.)
(mm)
024
2
286
130
Table 1 - Physical Data
030 036
2.5 3
298 329
136 150
RECIPROCATING
042
3.5
352
160
048
4
354
161
R-410A
3.3 5.9 5.0
1.5 2.7 2.3
0.059
1.50
1...20
9.1
24OO
2O
5O8
1/8 (800)
4.0 5.3
1.8 2.4
Piston
0.059 0.067
1.50 1.70
1...20 2...20
9.1 9.1
2400 2700
20 20
508 508
1/8 (800) 1/4 (1050)
3...12 3...12
4.3 4.3
1000 1200
8xll 9.5x 12
203 x 279 241 x 305
1/3 1/2
2...12
4.3
0.073
1.85
2...20
10.2
27OO
2O
5O8
1/4 (1050)
3...12
4.9
14OO
9.5x 12
241 x 305
1/2
8OO
8xll
203 x 279
1/3
0.082
2.08
2...20
10.2
27OO
2O
5O8
1/4 (1050)
3...12
4.9
1600
9.5x 12
241 x 305
3/4
650 +/- 15
420 +/- 25
20x20x1
508x508x25
20x24x1
508x610x25
24x30x1
610x762x25
SCROLL
24x36x1
610x914x25
060
5
4O2
183
6.2
2.8
TXV
N/A
2...20
13.0
3000
20
5O8
1/3 (1100)
3...12
6.1
1750
10.5 x 12
267 x 305
1
*Required filter sizes shown are based on the AHRI (Air Conditioning, Heating and Refrigeration Institute) rated airflow at a velocity of 300 ft/min for throwawa'
type or 450 ft/min for high capacity type. Recommended filters are 1-in. (25.4 mm) thick.
AC Unit Size
24
30
36
42
48
60
X = Not Approved Combination
Table 2 - Minimum
5 kW
6OO
6OO
6OO
6OO
6OO
6OO
Airflow for Safe Electric Heater Operation
Minimum Airflow (CFM)
7.5 kW
75O
75O
75O
75O
75O
75O
10 kW
75O
75O
75O
75O
75O
75O
15 kW
X
X
1050
1050
1050
1050
2O kW
X
X
X
X
1400
1400