10 INTRODUCTION
REFRIGERATION/ELECTRICAL SPECIFICATIONS
CMCT (404A)
CABINET START RUN
MODEL MFG. MODEL HP VOLTS AMPS AMPS
CMCT-4 Copeland KAGB-005E-IAA-222 1/2 115 45 8.0
CMCT-6 Copeland KAGB-005E-IAA-222 1/2 115 45 8.0
CMCT-8 Copeland KAJB-007E-IAA-222 3/4 115 59 12.0
CMCT-10 Copeland KALB-010E-CAV-221 1 230/208 33.5 8.1
REFRIGERATION CYCLE (80° Ambient)
CABINET REFRIG. DEFROST CAP. CONTROL CAVITY
MODEL CYCLE CYCLE REFRIG. OZ. TUBE SUCT. DISCH. SETTING TEMP.
CMCT-4 8.0 - 115V 6.8 - 115V 404A 22 8' x .042 ID 2# 225# No. 7 -22°F
CMCT-6 8.0 - 115V 8.4 - 115V 404A 23 8' x .042 ID 5# 223# No. 7 -19°F
CMCT-8 12.0 - 115V 12.0 - 115V 404A 27 7' x .049 ID 2# 228# No. 7 -22°F
8.1 - 230V 6.7 - 230V
CMCT-10 404A 29 7' x .054 ID 2# 223# No. 7 -27°F
4.8 - 115V 4.8 - 115V
NOTE: Refer to Data plate for refrigerant type and charge.
Condenser Fan ............G.E. 5KSM51GG37845 or Temperature Control ........RANCO A10-4491-00
5KPM51BL-40466 (Reversible Motor)
230 - V.E.M.S. ESP-L35-EM2 Back Pressure Valve ............Sporlan 10# setting
CRO-4-0-20
Time Clock..............115 Paragon 145-00B (24 Hr.) CRO-6-0-60 (CMCT-10)
230V Paragon 145-20B (24 Hr.)