INTRODUCTION 11
ECMCT REFRIGERATION/ELECTRICAL DATA
Export Models (R-404A)
ECMCT-4 OHMS WATTS AMPS VOLTS
Def. Heater on Bottom side
72.4 582 2.7 215
of Top Coil
Control Bellows Heater below
5375 9 .04 215
Def. Controls
End Breaker Heater behind
3071.4 15 .07 215
each End Breaker
Glass Heater around
826.9 56 .26 215
Front Glass
Heated Glass Lid
41.3 14 .58 24
(each)
ECMCT-6 OHMS WATTS AMPS VOLTS
Def. Heater on Bottom side
51 904 4.2 215
of Top Coil
Control Bellows Heater below
5375 9 .04 215
Def. Controls
End Breaker Heater behind
3071.4 15 .07 215
each End Breaker
Glass Heater around
565.8 82 .38 215
Front Glass
Heated Glass Lid
26.1 22 .92 24
(each)
COMPRESSOR AMPERAGE
CABINET RUN CAP.
MODEL MFG. MODEL HP VOLTS LRA AMPS OZ. TUBE
ECMCT-4 Copeland KAJB-010E-CAV 1 200 40 8.0 20 8' x .042
ECMCT-6 Copeland KAJB-010E-CAV 1 200 40 8.0 25 8' x .042