EasyManua.ls Logo

Carrier COMFORT 50EZ-A - Physical Data

Carrier COMFORT 50EZ-A
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
PHYSICAL DATA -- UNIT 50EZ--A
UNIT SIZE 50EZ --- A24 50EZ --- A30 50EZ --- A36 50EZ --- A42 50EZ --- A48 50EZ --- A60
NOMINAL CAP ACITY (ton) 2 2.5 3 3.5 4 5
SHIPPING WEIGHT} (lb)
(kg)
327
148
340
154
343
156
419
190
437
198
462
210
COMPRESSOR QUANTITY 1
TYPE SCROLL COMPRESSOR
REFRIGERANT R---410A
Refrigerant (R --- 410A) Quantity (lb)
Quantity (kg)
9.6
4.4
10.2
4.6
7.9
3.6
10.0
4.5
9.6
4.4
12.3
5.6
METERING DEVICE ID TXV
ORIFICE OD (in.)
(mm)
0.032 (2)
.81
0.035 (2)
.89
0.037 (2)
.94
0.038 (Left OD Coil)
0.040 (Right OD Coil)
.97/1.02
0.046 (2)
1.2
0.052 (2)
1.3
OUTDOOR COIL
Rows... Fins/in.
face area (sq. ft.)
2...21
11.9
2...21
11.9
2...21
11.9
2...21
13.6
2...21
13.6
2...21
17.5
OUTDOOR FAN
Nominal Airflow (CFM)
Fan Diameter ( in.)
Fan Diameter (mm)
Diameter Motor HP (RPM)
2700
24
610
1/5 ( 810)
2700
24
610
1/5 ( 810)
2700
24
610
1/5 ( 810)
3100
26
660
1/5 ( 810)
3100
26
660
1/5 ( 810)
3100
26
660
1/5 ( 810)
INDOOR COIL
Rows... Fins/in.
face area (sq. ft.)
3...17
3.7
3...17
3.7
3...17
3.7
3...17
4.7
3...17
4.7
3...17
5.7
INDOOR BLOWER
Nominal Cooling Airflow (CFM)
Size (in.)
(mm)
Motor (HP)
800
10x10
254x254
1/2
1000
10x10
254x254
1/2
1200
11x10
279x254
3/4
1400
11x10
279x254
3/4
1600
11x10
279x254
1.0
1850
11x10
279x254
1.0
HIGH --- PRESSURE SWITCH (psig)
Cutout
Reset (Auto)
650±15
420±25
L O S S --- O F --- C H A R G E / L O W --- P R E S S U R E
SWITCH
(Liquid Line) (psig)
Cutout
Reset (Auto)
20±5
45±10
20±5
45±10
RETURN ---AIR FILTERS*{
throwaway (in.)
(mm)
20x20x1
508x508x25
20x24x1
508x610x25
24x30x1
610x762x25
24x36x1
610x914x25
*Required filter sizes shown are based on the larger of the ARI (Air conditioning and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of
300 ft/minute for throwaway type or 450 ft/minute for high ---capacity type. Air filter pressure drop for non ---standard filters must not exceed 0.08 IN. W.C.
{ If using accessory filter rack refer to the filter rack installation instructions for correct filter size and quantity.
} For 460 volt units, add 14 lb (6.4 kg) to the weight.
A-Weighted Sound Power Level (dBA)
MODEL 50EZ---A
STANDARD
RATING
(dBA)
TYPICAL OCTAVE BAND SPECTRUM (dBA) (without tone adjustment)
125 250 500 1000 2000 4000 8000
2 4 --- --- --- 3 0 76 57.0 65.5 72.0 71.0 67.0 62.0 53.0
3 0 --- --- --- 3 0 / 5 0 76 60.5 67.5 72.0 70.0 67.0 61.0 51.5
3 6 --- --- --- 3 0 / 5 0 77 63.0 68.0 73.0 71.0 67.0 62.0 55.0
4 2 --- --- --- 3 0 / 5 0 78 65.0 68.5 74.5 72.5 69.5 64.5 56.5
4 8 --- --- --- 3 0 / 5 0 78 62.0 68.5 74.0 72.5 70.0 64.0 56.0
6 0 --- --- --- 3 0 / 5 0 76 63.0 66.5 69.5 71.0 66.0 65.0 59.0
NOTE: Tested in accordance with ARI Standard 270 (not listed in ARI).