(SW1-5 and SW4-3 set to OFF, except as indicated. See notes 1 and 2.)
Unit Size:
0801714
Clg/CF Switch settings External Static Pressure (ESP)
Clg Switches SW2-3 SW2-2 SW2-1 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Clg Default: OFF OFF OFF 1085 1095 1095 1100 1100 1095 1090 1095 1085 1080
CF Switches SW3-3 SW3-2 SW3-1
Low Clg Default: OFF OFF OFF 550 550 545 535 520 See note 4
Cooling Airflow (SW2)
Low Cooling Airflow (SW3)
OFF OFF ON 550 550 545 535 520 See note 4
OFF ON OFF 705 710 710 710 700 See note 4
OFF ON ON 885 900 910 910 910 905 900 895 885 875
ON OFF OFF 1085 1095 1095 1100 1100 1095 1090 1095 1085 1080
ON OFF ON 1255 1265 1265 1270 1275 1275 1255 1220 1190 1160
ON ON OFF 1420 1410 1375 1345 1310 1280 1255 1220 1190 1160
ON ON ON 1420 1410 1375 1345 1310 1280 1255 1220 1190 1160
Maximum Clg Airflow
2
1445 1410 1375 1345 1310 1275 1255 1220 1190 1160
CF Switches SW3-3 SW3-2 SW3-1
Cont. Fan Default: OFF OFF OFF 550 550 545 535 520 See note 4
Continuous Fan Airflow (SW3)
OFF OFF ON 430 410 390 370 350 See note 4
OFF ON OFF 485 475 455 440 420 See note 4
OFF ON ON 550 550 545 535 520 See note 4
ON OFF OFF 550 550 545 535 520 See note 4
ON OFF ON 550 550 545 535 520 See note 4
ON ON OFF 550 550 545 535 520 See note 4
ON ON ON 550 550 545 535 520 See note 4
Heating (SW1)
High Heat Airflow
3
1235 1245 1250 1255 1255 1260 1255 1220 1190 1160
Low Heat Airflow
3
1005 1010 1015 1015 1020 1000 995 990 980 970
Unit size:
0802120
Clg/CF Switch settings External Static Pressure (ESP)
Clg Switches SW2-3 SW2-2 SW2-1 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Clg Default: OFF OFF OFF 1745 1755 1755 1760 1755 1750 1745 1725 1705 1685
CF Switches SW3-3 SW3-2 SW3-1
Low Clg Default: OFF OFF OFF 700 710 750 725 750 See note 4
Cooling Airflow (SW2)
Low Cooling Airflow (SW3)
OFF OFF ON 700 710 750 725 750 See note 4
OFF ON OFF 830 860 870 890 960 See note 4
OFF ON ON 1045 1045 1060 1070 1070 1070 1095 1090 1080 1070
ON OFF OFF 1215 1220 1245 1240 1235 1235 1225 1220 1235 1235
ON OFF ON 1370 1370 1390 1390 1400 1395 1400 1390 1390 1385
ON ON OFF 1745 1755 1755 1760 1755 1750 1745 1725 1705 1685
ON ON ON 1745 1755 1755 1760 1755 1750 1745 1725 1705 1685
Maximum Clg Airflow
2
1920 1920 1945 1945 1945 1960 1950 1940 1915 1900
CF Switches SW3-3 SW3-2 SW3-1
Cont. Fan Default: OFF OFF OFF 700 710 750 725 750 See note 4
Continuous Fan Airflow (SW3)
OFF OFF ON 700 710 750 725 750 See note 4
OFF ON OFF 830 860 870 890 960 See note 4
OFF ON ON 1045 1045 1060 1070 1070 1070 1095 1090 1080 1070
ON OFF OFF 1215 1220 1245 1240 1235 1235 1225 1220 1235 1235
ON OFF ON 1215 1220 1245 1240 1235 1235 1225 1220 1235 1235
ON ON OFF 1215 1220 1245 1240 1235 1235 1225 1220 1235 1235
ON ON ON 1215 1220 1245 1240 1235 1235 1225 1220 1235 1235
Heating (SW1)
High Heat Airflow
3
1340 1355 1370 1385 1380 1385 1400 1400 1385 1380
Low Heat Airflow
3
1080 1115 1115 1120 1125 1135 1125 1120 1125 1110
Table 17 – Cooling
4
and Heating Air Delivery - CFM (Bottom Return
5
with Filter) (Continued)