3
MODEL NUMBER NOMENCLATURE
50XL 0 1024 3
Type of Unit
50XL - Packaged
Air Conditioner
Nominal Cooling Capacity
024 - 2 Ton
030 - 2.5 Ton
036 - 3 Ton
042 - 3.5 Ton
048 - 4 Ton
060 - 5 Ton
N/A
– – –
Options
BT - AL evap, vinyl condens
CC - AL evap, CU condens
CU - CU evap & condens
TP - Base unit with tin plated
indoor coil hairpins
TV - TP with vinyl coating on outdoor coil
TC - TP with AL indoor coil and
CU/CU outdoor coil
Only used if ordering an option
– –
Series
Electrical Supply
3- 208/230-1-60
Packaging
LEGEND
AL - Aluminum
CU - Copper
ARI* CAPACITIES
Cooling Capacities, Efficiencies
Unit 50XL Nominal Tons
Standard CFM
(High / Low Stage)
Net Cooling
Capacities -- Btuh
(High / Low Stage)
EER @A** SEER†
024 2 800 / 600 22,600 / 17,600 11.4 15.5
030 2--1/2 1000 / 700 28,600 / 21,400 11.6 15.0
036 3 1200 / 850 34,600 / 24,400 12 15.0
042 3--1/2 1400 / 975 40,500 / 29,000 11.6 15.0
048 4 1600 / 1100 46,000 / 33,400 11 15.0
060 5 1750 / 1200 57,000 / 40,500 11 14.5
* Air Conditioning & Refrigeration Institute.
** ”A” conditions---80°F (26.6°C) indoor db/67°F (19.4°C) indoor wb & 95°F(35°C) outdoor db.
{ Rated in accordance with U.S. Government DOE D epar tmen t of Energy) test procedures and/or ARI Standards 210/240---94.
Notes:
1. Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on:
Cooling Standard: 80°F (26.6°C) db, 67°F (19.4°C) wb indoor entering --- air temperature and 95°F(35°C)dboutdoorentering---airtemperature.
2. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer.
LEGEND
dBA—Sound Levels (decibels)
db—Dry Bulb
SEER—Seasonal Energy Efficiency Ratio
wb—Wet Bulb
50XL