14
336228-101 REV. A
1. Use Copper Wire (75ºC Min) Only Between Disconnect Switch And
Unit.
2. To Be Wired In Accordance With NEC And Local Codes.
3. If Any Of The Original Wire, As Supplied, Must Be Replaced. Use
The Same Or Equivalent Type Wire.
4. Replace Low Voltage Fuse With No Greater Than 5 Amp Fuse.
5. Connect R To R, G To G, Etc. See Outdoor Instruction For Details.
6. To change speed tap, move blue wire to desired terminal.
7. See airflow tables for tap usage.
NOTES
BRN - C
BLK - L
YEL - N
GRN/YEL - GND
BLU - 2
9
9
7
7
4
4
3
3
2
2
6
6
1
1
THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING
BLOWER MOTOR
ROTATION
COOLING CONTROL ONLY
FIELD POWER WIRING
PLUG
RECP
L1
GND
YEL
BLK
L2
DISCONNECT PER NEC
SEE RATING PLATE
FOR VOLTS & HERTZ
SEE NOTE #1
11
LEGEND
C
F
FM
GND
RECP
SPT
TRAN
COMMON
LOW VOLTAGE FUSE
FAN MOTOR
EQUIPMENT GROUND
RECEPTACLE
FAN SPEED TAP LOCATION
TRANSFORMER
UNMARKED TERMINAL
FIELD POWER WIRING
MARKED TERMINAL
PLUG AND RECEPTACLE
FM
GND
COMPONENT ARRANGEMENT
COM
208 V
230 V
24 V
TRAN
SYSTEM TRANSFORMER: 40.0 VA
FAN COIL: 5.0 VA
REMAINING VA AVAILABLE: 35.0 VA
SPEED TAP
SELECTION
LOW
MEDIUM
HIGH
ELEC HEAT
SEE NOTE 7
1
2
3
4
5
SEE NOTE #6
E
W3
W2
BRN
CR
WHT
G
GRY
WHT
BLU
VIO
BLU
208 V
230 V
COM
TRAN
RED
BRN
C
L
G
N
1
23
4
5
Speed Tap
Connections
Power
Connections
Motor Connections
BLU
BRN
BLK
GRN/YEL
YEL
YEL
W
THERMOSTAT
CONNECTION
GRN/YEL
WHT
WHT
FUSE
BRN
RED
RESISTOR
11
WHT - 4
A12364
Fig. 16 -- 336228--101