18.3.2 For the super-slim cassette with up-down panel 
18.3.2.1 Communication error between indoor unit and up-down panel 
F0  Displayed
F0  Displayed
Communication failure between 
indoor unit and up-down panel
Communication failure between 
indoor unit and up-down panel
Check the wire connection 
between up-down panel and 
indoor unit, is it right? 
Check the wire connection 
between up-down panel and 
indoor unit, is it right? 
Correct the connection 
Correct the connection No
Yes
Replace the indoor main PCB
Replace the indoor main PCB
No
Replace the up-down panel
Replace the up-down panel
 
18.3.2.2 Up-down panel is defective 
F1 Displayed
F1 Displayed
Up-down panel is defective
Up-down panel is defective
Retry if panel can up and 
down normally?
Retry if panel can up and 
down normally?
Check the wiring of 
left and right sensors
Check the wiring of 
left and right sensors
No
No
The up-down panel is defective. 
replace it 
The up-down panel is defective. 
replace it 
Yes
No
If panel can move slightly, power 
off, then restart the unit 2 minutes 
later. If the error still exists?
If panel can move slightly, power 
off, then restart the unit 2 minutes 
later. If the error still exists?
No
If panel can not move 
slightly, check the wiring 
of louver motors
If panel can not move 
slightly, check the wiring 
of louver motors
Yes
Reconnect
Reconnect
Replace the louver 
motors
Replace the louver 
motors
Reconnect
Reconnect
No
No
No