- 5 -
STEP 8
Plug in AC Cord.
NOTE: Sometimes when the AC Cord
is new it does not want to go in all the
way. Push firmly to force it in, if that is
the case.
STEP 9
Turn the Power Button ON. Wait 2
minutes for the amp to get hot, after the
2 minutes you should see the meter read
current. It will start slow then increase
up to 75mA, adjust it accordingly.
NOTE: Do Not turn ON the Standby
switch, leave it on STANDBY.
STEP 10
Check your meter at this point, if it goes
over 75mA, lower it by turning the bias
potentiometer with the screw driver,
clock wise, if it’s under 75mA bring it
up by turning the potentiometer the
other way.