4.1.2 Span/Zero Fine Adjust (Menu Code 8120)
(Calibration MENU -> 1. Calibration -> 2. Span/Zero Fine Adjust)
This mode is for fine tuning of scale after span Cal. Please put Max weight on the tray and adjust
A/D results at 60000, using the cursor key “
.
and Number key.
Select menu “Span/Zero Fine Adjust”
* If
is not set to zero press “ ZERO” key. Value
will update.
Put Max. Capacity weight on the tray
Use
key for fine adjust.
* Insert setting value by cursor key (for the fine tune)
” Increases Span value “
” to decrease Internal value “
Decreases Span value “
” to increase External value “
- Internal value 60012 needs to change 60000
Press X 12 Times to decrease internal value.
Menu Code
Internal Value
External Value
(Weight)
Pure setting value of Zero & Span
8120
0
0
S
PAN/ZERO FINE ADJUST
(1/
1
)
ZERO:[ 10730]
SPAN:[ 88133]
8120
60012
15005
S
PAN/ZERO FINE ADJUST
(1/
1
)
ZERO:[ 10730]
SPAN:[ 88133]
8120
60000
15000
S
PAN/ZERO FINE ADJUST
(1/
1
)
ZERO:[ 10730]
SPAN:[ 88145]