EasyManua.ls Logo

Casablanca Victorian User Manual

Casablanca Victorian
11 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
CIRCUIT BREAKER
(TRIP BREAKER FOR THE
CIRCUIT YOU WILL BE
WORKING ON)
FUSE BOX
(REMOVE FUSE FOR THE
CIRCUIT YOU WILL BE
WORKING ON)
18
84
70
CONTENTS
NOTES
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
MOUNTING RECOMMENDATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
FAN INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
CONTROL FEATURES:
 



 All wiring must be in accordance with the National Electric Code ANSI/NFPA 70-1993 and the appropriate local electrical
codes. The National Electric Code requires proper grounding as a precaution against electrical shock. A qualified electri-
cian should be consulted if you are unsure.
• Thisfanisdesignedtobeinstalledonanexistingelectricaloutletbox.TheoutletboxmustbeULListedforceilingfan
installations,ifitisnot,anewboxmustbeinstalled.Casablancaextensionpolesareavailableforslopedorhighceiling
installations.
 Thisceilingfanrequiresagroundedelectricalsupplyof120VAC,60Hzandaminimum15ampcircuit.Themaximum
currentrequirementforthefanwithlightxtureis3.8amps.Thefanusesabout1ampor100watts.Maximumlight
currentis2.8ampsor340wattsoflighting.
Where wire nuts are employed, be sure all bare wires are within the connectors. When installing the canopy hatch, make
sure all wires are within the canopy and that no wires are being pinched.
For best performance and for your warranty to be valid,
use only genuine Casablanca blades, light fixtures, and accessories.
Safety and the proper operation of your Casablanca fan both require a thorough knowledge of the
product and proper installation; therefore, before attempting to install and operate your Casablanca
fan, read this owner’s manual completely and carefully. Retain this manual for future reference.
BEFORE YOU START
CAUTION: To avoid possible electrical shock, make certain that electricity is turned off at
the circuit breaker or fuse box before attempting any installation procedure.
The blades in each pack are matched for
equal weight to assure smooth fan operation.
If more than one fan is being installed, be
careful not to mix blades from different
cartons.
Inspect the contents of your carton for
possible shipping or handling damage and
report any such damage directly to your
authorized Casablanca dealer.
Itisalwaysagoodideatohaveanassistant
to help with the installation.
When cleaning, painting, or working near
your fan, be very careful of the fan and
blades. Always turn the power OFF to the
ceilingfanbefore servicing it, workingon
it, or replacing light bulbs.
Neverinsertanythingintothepathofthe
fan blades while the fan is in operation.
• Neverinstallafanoverapoolorspa.
Neveroperateafanthathasbeendamagedin
any way. Contact Casablanca Fan Company by
calling1-888-227-2178,orcontactyourlocal
authorized Casablanca dealer for assistance
inobtainingservice.
Question and Answer IconNeed help?

Do you have a question about the Casablanca Victorian and is the answer not in the manual?

Casablanca Victorian Specifications

General IconGeneral
Number of Blades5
Motor Speeds3
Control TypePull Chain
Light KitOptional
Light Kit IncludedNo
Reversible MotorYes
Blade FinishWalnut
Mounting TypeDownrod Mount
MaterialWood

Summary

READ AND SAVE THESE INSTRUCTIONS

BEFORE YOU START

MOUNTING RECOMMENDATIONS

INSTALLATION INSTRUCTIONS

PERMA-LOCK™ HARDWARE

Details the Perma-Lock hardware used for downrod assembly and its secure installation process.

FAN PREPARATION

Guides on preparing the fan, including routing wires and installing the downrod into the motor coupling.

CROSSBAR MOUNTING BRACKET INSTALLATION

HANGING THE FAN

CANOPY ELECTRICAL CONNECTIONS

CANOPY HATCH INSTALLATION

BLADE HOLDERS & HARDWARE

BADGE STYLE BLADE HOLDER & BLADE

INTELI TOUCH INSTALLING THE W-32 WALL CONTROL

INTELI TOUCH SINGLE W-32 INSTALLATION

Step-by-step instructions for installing a single W-32 wall control for the Inteli-Touch fan.

INTELI TOUCH DUAL W-32 INSTALLATION

Instructions for installing two W-32 wall controls for a three-way circuit setup.

INTELI TOUCH OPERATION POWER

INTELI TOUCH OPERATION SPEED CONTROL

To select the desired fan speed

Explains how to select and set the fan speed using the Inteli-Touch controls.

INTELI TOUCH • REVERSING AIRFLOW

INTELI TOUCH LIGHT

TROUBLESHOOTING

NO FAN OR LIGHT

Checks for issues when the fan or light is not operating.

FAN WOBBLES OR SHAKES EXCESSIVELY

Solutions for excessive fan wobbling or shaking during operation.

FAN NOISY DURING OPERATION

Steps to diagnose and fix noisy fan operation.

DOES NOT RUN ON LOW SPEED

Troubleshooting steps for when the fan fails to operate on low speed.

FAN OR LIGHTS APPEAR TO OPERATE BY THEMSELVES (CHANGING SPEED OR INTENSITY), WALL CONTROL OPERATION IS INTERMITTENT

Diagnosing and resolving intermittent or self-activating fan/light operation.

Related product manuals