cESTIMATION-------------------------
......
36
~DEBUG I
Change
the
program
When using this
program,
the user will have
to
change the following
two
points:
(1)
Amount
of
data
Change
the
number
500
in the IF
statement
(P>500)
in line
170
to
the
actual
number
of
data
items.
The
number
of
records for
the
preparation
of
a
CETL
file
should
also be changed
to
the
actual
number
of
data
items + 1.
The
smaller
the
amount
of
data,
the higher
the
speed
of
input/output
operation,
especially
when
a
cassette
tape
is
involved.
(2}
File
number
If file 1
is
already
occupied,
create
the file
in
another
file
area
using
CETL
and
change
the
BASIC
program
as follows: · ·
Assign
the
file
number
actually
used
to
the first
parameter
of
the
FL
functions
in
lines
170,
180,
330,
360,
670,
680,
760,
and
770.