MAMBA MONSTER X SPECIFICATIONS
Application
Guidelines
1:8th scale RC hobby vehicles weighing up to 15lbs
Input Voltage
Range
Min: 2S LiPo, Max: 6S LiPo, 25.2V
BEC
Specifications
Adjustable: 5.5V, 6.0V, 7.5V, or 8.0V (8A Peak), default 5.5V
Waterproof Yes*
Sensors
Yes, with purchase of optional sensor harness. (Castle P/N 011-
0108-00)
Product Use
Statement**
Applying voltages higher than 25.2V will cause irreparable
damage to your controller.
Recommended battery capacity for 1:8th scale vehicles is
5000mAh or larger. We recommend using 30C continuous
discharge or higher LiPo batteries (or high quality 25C batteries
such as Traxxas® Power Cell).
The Mamba Monster X has 6.5mm bullet connectors directly
on the ESC and the battery input wires are bare. You must add
the connector of choice to the battery leads. We recommend a
high-current connector rated for 70+ amps.
The Mamba Monster X is not intended for human or animal
propulsion.
RECEIVER CONNECTION
RX Wire Plug the RX wire into the throttle (#2) channel on your receiver.
AUX Wire
The AUX wire allows you to adjust a setting “on-the-fly” using
an auxiliary channel on your receiver. The AUX wire function is
disabled by default and is programmable via Castle Link. Plug
this wire into the auxiliary (#3/#4) channel on your receiver.
Contact
Castle Creations, Inc.
540 North Rogers Road
Olathe, KS 66062
(913) 390-6939 (ext. #1 Support, #2 Sales)
Support: www.castlecreations.com/contact-support
Sales: www.castlecreations.com/contact-service
Website: www.castlecreations.com/mambamonsterx
TRANSMITTER PROGRAMMING REFERENCE
AUDIBLE ALERT REFERENCE
• •
Start Fail
Low Voltage Cutoff
Over-Current
• • •
Sensors Lost
• •
Radio Glitch
Over-Temperature
Excessive Load
• •
AUX Wire Radio Glitch
BEC Over-Temperature
• • • •
Data Log Full Warning
Motor Over-Temperature
1.Brake/Reverse Type 3. Brake Amount 5. Motor Type
• With Reverse* • 25% • Brushless*
• Without Reverse • 50%* • Brushed Reversing
• Crawler Reverse • 75%
100% 6. Motor Direction
2.Voltage Cutoff • Normal*
• Auto-Lipo* 4. Drag Brake • Reverse
None Disabled*
10%
20%
30%
Crawler Full On
*Default Setting
*Not intended for operation while submerged in liquid. If unit is operated in wet conditions, rinse with fresh
water to remove dirt or corrosives, then fully dry unit.
**Failure to adhere to the Product Use Statement constitutes a violation of the warranty agreement, and will
result in non-warranty service fees to repair or replace damaged products.