5252
REFUELING
◆◆
LP-Gas Equipment
For Standard LP-Gas Tank
1. Park the lift truck on level ground with the
parking brake applied, the transmission in
NEUTRAL, lock knob in lock position, the
forks lowered and the engine running at
low idle.
2. Close the fuel valve at the LP-Gas tank.
Run the engine until it stops, then turn off
the starter switch.
3. Disconnect the fuel supply line.
4. Loosen the retaining clamps, remove the
pin and tank.
NOTICE:
1. MOUNT THE TANK PROPERLY. Use
holes in the collar for horizontal mounting
and the slot in the foot ring for vertical
mounting to insure full usage of the fuel.
2. Open the valve slowly so the hose and tank
pressure can equalize or the valve may shut
off.
3. For proper operation of LP-Gas system,
use HD-5 LPB fuel.
Only trained, authorized personnel
should fill or exchange LP-Gas tanks.
Personnel engaged in filling LP-Gas
tanks should wear protective clothing
such as face shield, long sleeves and
gauntlet gloves.
Do not refuel or store LP-Gas powered
lift truck near underground entrances,
elevator shafts, or other places where
LP-Gas could collect in a pocket and
cause potential danger for an explosion.
Examine all LP-Gas tanks before filling,
and again before reuse, for damage to
the valves, liquid gauge, fittings and
hand wheels.
All defective or damaged LP-Gas tanks
must be removed from service.
The careless handling of LP-Gas tank
can result in a serious accident.
To reduce the risk of damage to tanks,
use extreme care when transporting
them.