REFUELING
5. Check to be sure the replacement tank is of
the correct type.
6. Inspect the replacement tank for damage
such as dents, scrapes or gouges and for
leakage at valves or threaded connections.
7. Check for debris in the relief valve and for
damage to various valves and the liquid
level gauge.
8. Inspect the couplings for deterioration,
damage or missing flexible seals.
9. Clamp the tank securely.
10. Connect the fuel supply line.
11. Turn the fuel valve on by slowly turning it
counterclockwise. If the fuel valve is
opened too quickly, a back pressure check
valve will shut off the fuel supply. If this
happens, close the fuel valve completely,
wait five seconds, and then open the fuel
valve very slowly.
12. Inspect the LP-Gas fuel lines and fittings
with a soap solution after filling the tank or
when looking for leaks.
100717A
LP-Gas tank must not extend past the
counterweight.
LOCATION
33-1/2# tank (A) Use pin (B)
43-1/2# tank (B) Use pin (A)
101618
B
B
A
A
WARNING
!