Technicalinst. guide Limpido XC2 v4.0
2. Technical specifications
Power supply voltage 230V~ AC 50/60Hz
Power consumption
PF10I040 90W
PF10I033 120W
PF10I031 150W
Dimensions:
Box: 290 x 350 x 150mm
Cell: 312 x 100 x 120mm
Packing box: 575 x 400 x 170mm
Weight Box: 1.04 kg / Cell: 1.35 kg
Installation
Box: Wall fasteners (4 screws/wall plugs supplied)
Cell: On 50mm diameter PVC tubes (union fittings not includ-
ed)
Protection factor Box: IP-45 / Cell: IP-55
Maximum treated volume
PF10I040 Maximum 60 cubic metres
PF10I033 Maximum 100 cubic metres
PF10I031 Maximum 160 cubic metres
Recommended salt level 2.5 to 5 g / litre
Cell cleaning Automatic using polarity reversal
Maximum pressure (cell) 3 bars
Maximum flow rate (cell) 22 m3/h
3. Description
3.1. The principles of electrolysis
Salt water electrolysis separates salt (NaCl) into sodium (Na) and Chlorine (Cl). The chlorine is im-
mediately dissolved in the water to produce hypochlorous acid (HClO). This powerful disinfectant
destroys bacteria and algae before turning back into salt.
The quantity of chlorine needed to disinfect a swimming pool increases with the water temperature
and pH.
Chlorine production must be adjusted to the environment and water characteristics:
• water conductivity
www.c-
cei.fr
3