Technicalinst. guide Limpido XC2 v4.0
The calculated production time is (in hours): (Pool temperature - Minimum temperature*) + 1.
*The minimum temperature (15°C by default), can be configured. The calculated production time
can therefore be influenced.
There will be no production below this minimum temperature.
Default calculated production time (minimum temperature = 15°C);
Pool water
temperature
10 15 20 25 30 35
Production
time in AU-
TO mode
0h 1h 6h 11h 16h 21h
Production time calculated using a minimum temperature = 12°C;
Pool water
temperature
10 15 20 25 30 35
Production
time in AU-
TO mode
0h 4h 9h 14h 19h 24h
However, it is not recommended to lower the minimum temperature below 12°C in order to protect
the electrolysis cell plates from low temperature operation, as this would reduce their service life.
If production time seems insufficient, make sure the pool volume is set to the maximum in order
to optimise chlorine production (see 6.3.4), then, if necessary, use the ON mode (24h/24h) or the
PROG mode (by entering the required number of hours in "Prog hours". (see 6.3.5)