All programming are to be done in DISARM mode of the system.
After entering the Master Password for the first time, the system remains in Programming mode for 60 secs.
So, in case more than one programming is to be done, the system will not ask for Password again within 60 seconds of
the first programming.
Hence in such cases, the steps of “Enter Password + #” would get void in all the programming steps.
The Master Passwords can be changed as described below:
Press “SET”
Enter Old Password + #
Keep Pressing 2 to select “Password Chng”
Press #
Enter New 4 digit Password + # + Quick Exit
Alternately, Master Password can change User Passwords also as explained below:
Press “SET”
Enter Master Password (1234) + #
Keep Pressing 2 to select “Password Chng”
Press #
Press to select the desired User Password to be changed
Enter New 4 digit User Password + # + Quick Exit
Note: The Master Password can change User’s Password but cannot view their Passwords.
: After entering any Password if another Password is to be used before elapse of 60 seconds, press
“Quick Exit” twice.
: While changing Password, if the Password being entered is used by someone, it will display “Invalid Password”.
Same is true in case Password being entered is “0000”.
. Password Operation On / Off .
.
This feature allows ARMING of the system with or without Master Password.
Press “SET”
Enter Master Password (1234) + #
Keep Pressing 2 to select “Password Optn”
Press #
Press key “UP” or “DOWN” to select OFF or ON for this feature
Press # + Quick Exit
. Record of History .
The system keeps a record of last 100 events of ARM, DISARM and Intrusions with date and time of events.
To View the records:
Press (History).
Enter Master Password (1234) + #
Press “UP” or DOWN” to select a particular record.
To Clear the records:
Press (History).
Enter Master Password (1234) + # + Back Space + Master Password (1234) + #
Note: After 100 records, the very first record gets deleted to record the 101
st
event.
Explanation of the Display on the main unit:
Display Meaning
SN = 00 to 99 denoting Serial Number of the History
ZZ = Wired Zone Number / Wireless Sensor number
01 to 75 in case of Wireless Sensor
98 in case of Operations through Telephone Line
99 in case of “Main Unit”
W1 to W8 in case of Wired Zones
DDDDDD= It either of the following action:
= Armed - means the system was armed at that time.
If, ZZ=99 then the system was Armed from
the main unit.
= Disarm - means the system was disarmed at that time
= Intrus – means intrusion from the displayed wired Zone or
wireless Sensor
= Panic – means Panic key was pressed
= Batlow – means battery is low of the displayed wireless
Sensor or the main unit in case of ZZ=99
= Bypass – means the system was Armed in Bypass mode
= PwWrng – Wrong Password entered 3 times consecutively.