EasyManua.ls Logo

CCL BAS-G - Battery Mode - Power Switch off in; CMS (Central Monitoring Station); Date; Time Setting

CCL BAS-G
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Enter Master Password (1234) + #
Keep Pressing 2 to select “Holidays”
Press #
Press “Up Arrow” key to select day 1, 2, 3, ……
Press “#”
Enter the date + Month + Year (All in 2 digits format)
Here, “Back Space” key can be used to edit the entered digits.
Press “#” to confirm
Press “Quick Exit” to exit
Deletion of day:
Press “SET”
Enter Master Password (1234) + #
Keep Pressing 2 to select “Holidays”
Press #
Press “Up Arrow” key to select day 1, 2, 3, ……
Press Back Space”
Press “#” to confirm deletion
Press “Quick Exit” to exit
Default: No holidays.
Note: If wrong date is entered, system will display “Invalid Date”.
: Today’s date or previous date is considered wrong by the system
. Battery Mode - Power Switch Off .
When AC mains is not present, the system shifts to the battery mode and keeps the system running.
If it is required to switch OFF the system when running in Battery mode, do the following programming.
Procedure: Press BACK SPACE
Enter Master Password (1234) + # + 2 + #
System will switch OFF.
Note: The system gets ON automatically when the mains AC is restored.
: The system cannot be switched OFF if mains AC is connected to it.
: The system has built-in rechargeable Li batteries. If longer back up is required then additional rechargeable 12V
7AH battery can be connected with an Optional Adapter having charger.
. CMS (Central Monitoring Station) .
With this feature, all or selected events are logged with a Central Monitoring Station maintained by Copper
Connections Pvt Ltd. In the event of any intrusion, the attendant at CMS will take necessary action (as desired by
the user). This facility can be availed from Copper Connections Pvt Ltd on annual charges
basis.
Programming for activation of the feature:
The system is to be given the CMS telephone number through programming.
To Enable the CMS feature:
Press “SET
Enter Master Password (1234) + #
Keep Pressing 2 to select “CMS Settings”
Press #
Press 2
Press 6 and select CMS = Enable or Disable. Press 6 again to alter Enable / Disable.
Press #
Press “Quick Exit”
To Enter Telephone Number of the CMS
Press “SET
Enter Master Password (1234) + #
Keep Pressing 2 to select “CMS Settings”
Press #
Press 1
Press “Back Space”
Enter the Telephone Number
Press #
Press “Quick Exit”
. Date / Time Setting .
Press “SET
Enter Master Password (1234) + #
Keep Pressing 2 to select “Set Date”
Press #
Press YY + # + MM + # + DD + # + HH + # + MT + # + d + # + Quick Exit
Where, YY= Year
MM= Month
DD= Date