Press BACK SPACE + # + Quick Exit
Deletion of All Wireless Sensor registration
This process deletes all the Signal Repeaters & Wireless Remotes connected to the system. If only one is to be
deleted then delete all the Remotes/Signal Repeaters and register the required ones again.
Press “SENSOR
Enter Master Password (1234) + #
Press 3 + # + Quick Exit
. Wireless Sensor Operating Mode .
Press “SENSOR” Key
Enter Master Password (1234) + #
Press 2 + 2
Press “UP” or DOWN” key to select the desired Wireless Sensor
Press MODE to choose any of the following modes of Sensor:
Mode
Function of Sensors in the Zone
Normal ARM
These Wireless Sensors will function in case of
system being ARMED or “BY Pass ARMED.”
Disable
This Wireless Sensor will not work.
ARM Bypass
These Wireless Sensors will function only when
System is ARMED & not when “By-Pass
AREMD”.
Traitor Mode
Whenever this Wireless Magnetic Sensor is
open, system will give beeps. This would
happen only when system is DISARMED.
Always ARMED
These Wireless Sensors will always remain in
ARMED condition whether the system is
ARMED or DISARMED.
Silent Normal
These Wireless Sensors will function in case of
system being ARMED or “BY Pass ARMED.”
But there will be no siren sound.
Silent Always
These Wireless Sensors will always remain in
ARMED condition whether the system is
ARMED or DISARMED. But there will be no
siren sound.
Press # + Quick Exit
Note: In default all Wireless Sensors get registered in “Normal ARM” mode.
: All modes will not be selectable for all type of Sensors. The availability shall be as per the table given below:
. Wired Zones Operating Mode .
Press “SENSOR” Key
Enter Master Password (1234) + #
Press 2 + 1
Select the desired Wired Zone from1 to 8, by pressing “Up” or “Down” key.
Press MODE to choose any of the following modes of Sensor:
Mode
Function of Sensors in the Zone
Normal ARM
All Sensors of this Zone will function in case of
system being ARMED or “BY Pass ARMED.”
Disable
No Sensor of this Zone will work
ARM Bypass
All Sensors of this Zone, will function only
when System is ARMED & not when “By-Pass
ARMED”.
Sensor Type
Modes
Normal
ARM
Disable
ARM
Bypass
Traitor
Always
ARM
Silent
Normal
Silent
Always
Remote
Magnetic Sensor
Vibration Sensor
PIR
Panic
Gas
Smoke
Heat
Heat/Humidity
Beam Sensor
Tamper
Wireless Key Board