EasyManua.ls Logo

CDI computorq 3 User Manual

CDI computorq 3
6 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
FOR YOUR PERMANENT FILE
19220 SAN JOSE AVENUE • CITY OF INDUSTRY, CA 91748 • USA
(626) 965-0668
Find other ne torque products at WWW.CDITORQUE.COM
WRENCH MODEL NUMBER:
WRENCH SERIAL NUMBER:
Form 20-1800-CDI
6/2010 Rev. N/C
Made in USA with US and Global Components
For Warranty Claims, Contact CDI Torque Products
at (626) 965-0668.
LIMITED WARRANTY
The CDI Computorq 3 Electronic Torque Wrench
is backed by a one year warranty. This warranty
covers manufacturer defects and workmanship.
The warranty excludes misuse, abuse and normal
wear and tear. Exclusion is not allowed in some
states and may not apply. This warranty gives
you specific legal rights, and you may have other
rights, which vary from state to state.
IMPORTANT ENVIRONMENTAL NOTES:
1. This equipment may contain hazardous materials which can be
harmful to the environment.
2. Do not dispose of this equipment as municipal waste. Return it
to the distributor or a designated collection center.
Thank you for caring about our environment!
cOMPUTORq 3
ELEcTRONIc
TORqUE WRENcH
OPERATION MANUAL
Question and Answer IconNeed help?

Do you have a question about the CDI computorq 3 and is the answer not in the manual?

CDI computorq 3 Specifications

General IconGeneral
BrandCDI
Modelcomputorq 3
CategoryTools
LanguageEnglish

Summary

Limited Warranty

Important Environmental Notes

Safety Messages

Risk of Flying Particles

Over-torquing, out-of-calibration angle wrench, or broken tools can cause injury or breakage.

Eye Protection and Safe Usage

All users and bystanders must wear eye protection, use rated components, and follow safety procedures.

Preventing Wrench Damage

Avoid operating wrench when powered off, pressing keys during torque application, or using it to loosen fasteners.

General Safety Precautions

Includes avoiding extensions on handles, engaging the switch correctly, and verifying capacity.

Electrical Shock Hazard

Electrical shock can cause injury; plastic handle is not insulated. Do not use on live circuits.

Maintenance and Service

Authorized Service and Calibration

Service, repair, and calibration must be performed by CDI Torque Products only.

Internal Lubrication

The internal mechanism is permanently lubricated; do not attempt to lubricate it.

Cleaning Instructions

Wipe with a damp cloth; never use solvents, thinners, or immerse in liquids.

Storage Recommendations

Store wrench in protective tube at its lowest torque setting.

Introduction to Computorq 3

Display Features

Custom LCD display shows units, readings, and a 10-segment bar graph.

Setting Target Torque

Use UP/DOWN keys to scroll to desired target torque value (10%-100% of full scale).

Tracking Applied Torque

Display shows actual applied value with 0.20 second update rate while torque is applied.

Audible Tones and LED Indicators

LEDs and tones indicate torque levels: yellow (-10%), green (target), red (+10%).

Peak Hold Function

Display holds and flashes peak torque reading for 10 seconds after release.

Overload Warning

Rapid pulsing tone and display lock ('----') indicate torque beyond 125% of full scale.

Zero Functionality

Automatic self-calibration check and re-zero upon power on; manual re-zeroing possible.

Setup Memory

Wrench returns to last unit and torque setting selected upon power on.

Battery and Power Management

Battery Information

Uses two CR123 lithium cells for over 80 hours of continuous operation.

Power On and Off

Press and hold ON/ZERO to power on; press and hold for 5 seconds to power off.

Auto Power Off

Wrench powers off automatically after 2 minutes of non-usage to conserve battery.

Operator Instructions

Setup Procedure

Steps for powering on, selecting units, and pre-selecting desired torque using UP/DOWN keys.

Proper Hand Position

Grasp handle centered for highest accuracy; avoid grasping above or below.

Usage Guidelines

Torque using pulling motion, stop at green LED/tone, adjust for red LED over-torque.

Using Adapters, Extensions, and Universals

Adjusting Set Torque

Calculate adjusted torque setting when using adapters/extensions to maintain accuracy.

Extension Length Effects

Formula provided to calculate new torque output based on adapter/extension length.

Universal/Wobble Extension Limits

Do not exceed 15 degrees offset with universals; avoid long flex-drive extensions.

Specifications

Display and Measurement Modes

LCD features: display capacity, setting, tracking, peak hold, and accuracy details.

Dimensions and Part Numbers

Details on drive size, length, weight for specific part numbers.

Operating and Storage Conditions

Specifies temperature and humidity limits for operation and storage.

Battery Life and Replacement

Two CR123 lithium cells provide 80+ hours; replace when 'bAtt' is shown.

Please Note

Calibration Services

Contact CDI Torque Products for calibration services.

Required Test Equipment

Precision test bars, certified weights, or accurate torque source needed for calibration.

Error Display

Display showing 'Erro' indicates wrench damage; return for repair.

Storage Recommendation

Remove battery when storing for extended periods.

Certification

Conversion Table

Use of Extensions and Adapters

Torque Calculation Formula

Formula TW = (TA x L) / (L + A) to calculate new torque output with extensions.

Factors Affecting Accuracy

Adapter/extension length, wrench length, and hand position affect accuracy.