Manufacturing Access Control since 1985
Surface
mount
magnet
Armature
plate
Mounting
plate
Roll pin
5x16
Steel
washer
Rubber
washer
M8x25
screw
Cap
nut
installation
Manual
1 1 1 2 2 1 1 2
1
C3S11
300 Kg Surface Mount Electromagnetic lock
EN
PRODUCT PRESENTATION INSTALLATION
PACKAGE CONTAIN
- NFS 61-937.
- Monitored.
- Surface mount.
- Delivered with armature plate.
- Corrosion resistance.
- No mechanical wear.
- Ease of installation.
- Recommended for interior use.
- Fail safe (Door unlocked when power off).
- Holding force: 300kg.
- No residual magnetism.
- Built-in varistor: Built-in electronic
protection to eliminate back EMF.
- 10 year warranty.
- Dimensions (L x W x D):
250 x 43 x 27mm.
- Armature dimensions
(L x W x D):
185 x 38 x 11mm.
- Power supply: 12/24V dc.
- Power absorption:
- 12 V DC = 480mA,
- 24 V DC = 240mA.
ADC335 BS602
Recommended
power supplies
EC certication
WEEE & RoHS
IP42
Electromagnetic lock
M8
screw
Rubber washer
Roll pin
Steel washer
Cap nut
G0301FR0337V05
All the information contained within this document (photos, drawing, features, specications and dimensions) could be perceptibly different and can be changed without prior notice. cdvi.com
ELECTRICAL CONNECTIONS
The NO/NC signal only switches when
the door is closed with the power to it on.
12V dc Default setup
Terminal
block
Correspondence
+ 12 or 24V dc
- - 0 V
N.C NC (Normally closed)
COM COM
N.O NO (Normally open)
WITH BUILT-IN PCB BOARD
- Check the jumper position before connecting
the lock to the input current. A wrong position
could damage the lock. This type of damage
is not covered by the warranty.
- Make sure that the magnet and the armature
meet evenly over their entire mating surfaces.
The Armature plate must be able to pivot
slightly about its center mounting screw
to compensate for any door misalignment.
IMPORTANT NOTE
12V dc 24V dc
Voltage selection
jumpers
Cap nut
Armature
Fixing plate

Other manuals for CDVI C3S11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CDVI C3S11 and is the answer not in the manual?

CDVI C3S11 Specifications

General IconGeneral
Holding force300 kg
Input voltage12 - 24 V
Product colorSilver
Power consumption (12V)480 mA
Power consumption (24V)240 mA
Operating temperature (T-T)-20 - 60 °C
International Protection (IP) codeIP42
Weight and Dimensions IconWeight and Dimensions
Weight1750 g
Plate depth38 mm
Plate width185 mm
Plate height11 mm
Electromagnet depth43 mm
Electromagnet width250 mm
Electromagnet height27 mm