BIGDRY 10000 EXPERT CONNECTED58
ENGLISH
13. OK indicator light
14. Defrost mode
15. Full water tank
16. Low fan
17. High fan
Note: after 10 seconds, all indicator lights on the panel will go out.
Switch o indicator lights: activate this function to turn o all indicators that are illuminated.
Appliance operation:
Automatic humidity control adjustment function:
- If the “CO” (continuous) mode is selected for dehumidication, the device will continue to
operate regardless of the humidity level.
- In case the ambient humidity level is higher or equal to 3% or higher than the selected
humidity level, the compressor and the fan will be activated automatically. The device
indicator will light up.
- When the ambient humidity is 2% below the selected humidity level, the device will
automatically stop working. When the desired humidity is reached, the “OK” indicator light
will come on.
- If the device stops dehumidifying and the humidity in the room returns to 3% more or
higher than the selected humidity level, the dehumidier will automatically switch back
on after 3 minutes.
- According to the above, it is possible to maintain the room humidity at the previously set
level.
Auto Comfort (“AU”) function:
- The device will stop working in places where the ambient temperature is below 5 °C.
- In places where the ambient temperature is between 5 and 20 °C, the humidity level will
be automatically adjusted to 60%.
- In places where the ambient temperature is between 20 and 27 °C, the humidity level will
be automatically adjusted to 55%.
- In places where the ambient temperature is above 27 °C, the humidity level will be
automatically adjusted to 50%.
Drying function: (“CLOTH” indicator light)
- When this function is activated, the device will continue to operate regardless of the
humidity level when dehumidifying in “CO” (continuous) mode.
- Fan speed at full power and cannot be adjusted.