BREEZECARE 3000BREEZECARE 3000
3534
2.
PARTS AND COMPONENTS
Fig. 1.
1. Top cover
2. Mist block cover
3. Water tank frame
4. Handle
5. Water tank
6. Sensor
7. Power cord
8. Base
9. Control panel
10. Transducer
11. Air outlet
12. Buoy
Fig. 2.
1. Display
2. On/o
3. Timer
4. Speed level
5. Humidity
3.
BEFORE USE
Take the product out of the box.
Remove all packaging material and save the original box.
Make sure all parts and components are included and in good conditions. If any visible signs
of damage are observed, contact the Technical Support Service immediately.
4.
OPERATION
Note: The ideal relative humidity level for human comfort is between 45 % and 65 %. Excess
humidity shows up in the form of condensation on cold surfaces or cold walls in the room. To
measure the room’s humidity correctly, use a hygrometer.
Relative humidity in dierent environments suitable for people:
Bedroom, living room: 45-65 % RH
Patient’s room: 40-55 % RH
Room with computer, experiment equipment: 45-60 % RH
Room with piano: 40-60 % RH
Museum, exhibition hall, and library: 40-50 % RH
Place the device on a at surface.
Take out the top cover, ll the water tank and then put the top cover back.
Place the water tank on the main base.
Plug the device to a power supply. The display will light up and the device will beep. After 2
seconds, the display will turn o and the device will enter standby mode.
Press on/o, the device will start working under mist mode at level 2. The blue light indicator
will turn on. The control panel will display the current humidity and then will display Mist
mode level 2 after 15 seconds. One minute later, it will display current humidity and back to
Mist mode again repeatedly.
Press Max./Min. and choose between the 3 mist speed levels. The corresponding digit will be
displayed: 1-Low, 2-Medium, 3-High.
While current humidity is being displayed, press Max./Min. to check the current mist speed
level and press again to select a dierent speed level.
Timer
There are 12 timer settings: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10,11, 12 hours.
Press the Timer symbol, the display will show the rst timer option, “0”. Press the same
symbol repeatedly to select the desired operating time.
After 5 seconds of setting the desired time, the timer indicator will stop ashing indicating
the settings have been successfully saved.
After 1 minute, the display will show current humidity.
Press the Timer symbol until “-- --” is displayed or hold down the Timer symbol for 2 seconds
to cancel the timer.
When the timer is set, the display will show the remaining operating time.
Humidity
When the LED display is showing current humidity, press the Humidity symbol.
The humidity level can be set from 30 % RH to 90 % RH.
Every time the symbol is pressed, it will be increased by 5 %.
When it reaches 90 %, press again and the display will show “Co”. Do not operate the device
for 5 seconds to cancel the humidity setting function.
Once the desired humidity level is set, the light indicator will ash 5 times indicating the
settings have been saved. Then, the display will show the target humidity level every 1
minute.
Note: If the target humidity is higher than the current humidity, the humidication function