BREEZECARE 3000BREEZECARE 3000
3736
will work.
When the set humidity is 16 % RH higher than current humidity, the device will operate at mist
level 3.
When the set humidity is 10 % RH ~ 15 % RH higher than current humidity, the device will
operate at mist level 2.
When the set humidity is 1 % RH ~ 9 % RH, the device will operate at level 1.
When the target humidity is lower than the current humidity, the device will enter standby
mode.
Note: The mist speed cannot be adjusted under constant humidity function.
During operation, hold down the humidity symbol for 2 seconds to switch to Sleep mode. The
blue light indicator and the display will turn o.
Press any symbol to turn the display on again.
Long press the Humidity symbol to exit Sleep mode.
Auto shut-o system
When the tank runs out of water, the device will automatically stop operating. The red light
indicator will turn on.
Rell the water tank, and the device will continue operating with the previous settings. If the
tank is not relled, the device will turn o after 5 minutes.
Warnings:
Never run the humidier when there is no water in water the tank and water basin.
Only pour aroma oil into the aroma cotton. Do not pour any liquid other than clean water into
the water tank or water base.
5.
CLEANING AND MAINTENANCE
Use a soft, damp cloth to clean the surface of the device.
Do not use detergent, scouring pads, chemically treated cloths, gasoline, benzene, alcohol,
thinner, or other solvents, as these can scratch and damage the tank and cause water
leakage.
Do not immerse the product in water or any other liquid.
If scale is built up due to the use of hard water, it is recommended to:
Use cold boiled water or distilled water.
Clean the transducer, water tank and basin humidier every week.
Change the water in water tank more often to keep it fresh.
Make sure to pour out water from the water tank and dry the water basin before you store it
unused for a long time.
Clean the whole humidier and make sure that all parts of the humidier are dried completely
if it is supposed to be leaved unused for a long time.
Cleaning the transducer
Clean with clean water or citric acid if there is scale in it.
Brush o the scale from the surface.
Rinse the transducer with clean water.
Cleaning the humidier basin
Clean the water basin with soft cloth or use citric acid if there is scale in it.
If there is scale covering the security switch, drop citric acid for 2-5 mins on the scale and
clean it out with the brush.
Rinse the water basin with clean water.
Cleaning the ceramic lter
Clean the ceramic lter after using 1000L of water regularly. (This is approximate and
depends on water quality).
If the ceramic ball is dirty, it needs to be cleaned more frequently.
It can be dipped in vinegar about 5 minutes. Then rinse it with clean water.
Place the lter under the sun for 4~6 hours.
6.
TROUBLESHOOTING
Trouble Possible cause Solution
The light indicator is
o when switched
on
The humidier is not plugged
in.
Plug the humidier into a powered
electrical socket.
Power cord is damaged.
Stop using the device immediately
and contact the Technical Support
Service of Cecotec.
Humidier is defective or
malfunctioning.
The light indicators
is on when switched
on, but no mist
comes out
Humidier is not turned on.
Press the power button to turn it
on.
The target humidity is
reached.
Increase the target humidity or
change mode.