FORCECLIMA 12600 SOUNDLESS HEATING FORCECLIMA 12600 SOUNDLESS HEATING
68
ENGLISH ENGLISH
The cooling
good.
There is direct sunlight. Pull the curtain.
Doors or windows are
there are other sources of
heat.
Close doors and windows.
The air inlet or outlet is
blocked.
Clear obstructions.
The device
makes a lot
of noise.
The air conditioning is not
Compressor
does not
work.
There is frost. Wait for 3 minutes until the temperature is
lowered, and then restart the appliance.
Protection against
overheating system is
activated.
The remote
control does
not work.
There is too much distance
between the machine and
the remote control.
Let the remote control get close to the
air conditioning, and make sure that
the remote control directly faces to the
direction of the remote control receiver.
The remote control is not
aligned with the direction
of the remote control
receiver.
Batteries are dead. Replace batteries.
Displays ‘E1’. The room temperature
sensor is abnormal.
Service of Cecotec.
The display
The pipe temperature
sensor is abnormal.
Service of Cecotec.
1. Service information
1.1 Area verication
necessary to ensure that the risk of ignition is minimised. Before repairing the cooling system,
the following precautions must be observed:
1.2. Work procedure
and prevent it from mildewing.
-
wrapping post. Install the water plug and the drain cap.
- Remove the exhaust pipe and keep it properly.
- Cover the air conditioning with a plastic bag. Put the air conditioning in a dry place, keep it
out of the reach of children, and take dust control measures.
- Remove batteries of the remote control and keep them properly.
- Ensure that the body is placed in a dry place and keep all machine components properly.
Maintenance
Any person who is involved with working on or breaking into a refrigerant circuit should hold a
their competence to handle refrigerants safely in accordance with an industry recognised
6. TROUBLESHOOTING
Problems Possible causes Possible solutions
The air
conditioning
does not
work.
There is no electricity. Turn it on after connecting it to a socket
with electricity.
The full-tank indicator will
Discharge the water inside.
The room temperature is
too low or too high.
It is recommended using the appliance in at
the temperature of 7-35 ºC.
In cooling mode, the room
temperature is lower than
heating mode, the room
temperature is higher than
the set temperature.
Change the set temperature.
the room temperature is
very low.
The appliance is in a room with a
temperature below 17°C.