37
socket-outlet during cleaning or maintenance.
• Do not store the pressure washer outdoors or where it could freeze. The pump could be
seriously damaged.
6. TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
Smoke comes out
from the device.
Overheating, overload
or damaged motor.
Turn the device immediately of
and contact the Technical
Support Service of Cecotec.
Not enough
pressure.
• Water inlet filter is
clogged.
• Air from the hose
connections is entering
the pump.
• The nozzle or relief
valves are worn or not
the correct size.
• Clean the water inlet filter.
• Check that connections and
locking ring are properly
tightened.
• Contact the Technical Support
Service of Cecotec.
The pressure
washer does not
start up.
• The unit is pressurized.
• Plug is not well
connected or electric
socket is defective.
• Extension cord is too long
or wire size too small.
• Main voltage supply is
too low.
• Thermal safety switch
has tripped.
• Squeeze trigger on gun.
• Check plug, socket and fuse.
• Remove extension cord.
• Check that main supply
matches the voltage stated on
the product’s rating label.
• Switch the device off and
allow it to cool down.
Fluctuating
pressure.
• Pump is sucking in air.
• Clogged nozzle.
• Valves dirty or worn.
• Water seals worn.
• Check that hoses and
connections are tight.
• Clean with the cleaning kit
• Contact the Technical Support
Service of Cecotec.
• Contact the Technical Support
Service of Cecotec.
ENGLISH