PROBLEM CAUSE SOLUTION
Not enough
pressure.
Water inlet filter is
clogged.
Air from the hose
connections is entering
the pump.
The nozzle or relief valves
are worn or not the
correct size.
Clean the water inlet filter.
Check that connections and
locking ring are properly
tightened.
Contact the Technical Support
Service of Cecotec.
The pressure
washer does not
start up.
The unit is pressurized.
Plug is not well connected
or electric socket is
defective.
Extension cord is too long
or wire size too small.
Main voltage supply is
too low.
Thermal safety switch
has tripped.
Squeeze trigger on gun.
Check plug, socket and fuse.
Remove extension cord.
Check that main supply
matches the voltage stated on
the product’s rating label.
Switch the device off and allow
it to cool down.
Fluctuating
pressure.
Pump is sucking in air.
Clogged nozzle.
Valves dirty or worn.
Water seals worn.
Check that hoses and
connections are tight.
Clean with the cleaning kit
Contact the Technical Support
Service of Cecotec.
Contact the Technical Support
Service of Cecotec.
The motor stops
suddenly.
Extension cord is too long
or wire size too small.
Thermal safety switch
has tripped due to
overheating.
Remove extension cord.
Check that main supply
matches the voltage stated on
the product’s rating label.