ENGLISH
25
HIDROBOOST 1400
PROBLEM CAUSE SOLUTION
Not enough
pressure.
• Water inlet filter is
clogged.
• Air from the hose
connections is entering
the pump.
• The nozzle or relief valves
are worn or not the
correct size.
• Clean the water inlet filter.
• Check that connections and
locking ring are properly
tightened.
• Contact the Technical Support
Service of Cecotec.
The pressure
washer does not
start up.
• The unit is pressurized.
• Plug is not well connected
or electric socket is
defective.
• Extension cord is too long
or wire size too small.
• Main voltage supply is
too low.
• Thermal safety switch
has tripped.
• Squeeze trigger on gun.
• Check plug, socket and fuse.
• Remove extension cord.
• Check that main supply
matches the voltage stated on
the product’s rating label.
• Switch the device off and allow
it to cool down.
Fluctuating
pressure.
• Pump is sucking in air.
• Clogged nozzle.
• Valves dirty or worn.
• Water seals worn.
• Check that hoses and
connections are tight.
• Clean with the cleaning kit
• Contact the Technical Support
Service of Cecotec.
• Contact the Technical Support
Service of Cecotec.
The motor stops
suddenly.
• Extension cord is too long
or wire size too small.
• Thermal safety switch
has tripped due to
overheating.
• Remove extension cord.
• Check that main supply
matches the voltage stated on
the product’s rating label.