Cleaning the nozzle
• A clogged or partially clogged nozzle can signicantly reduce water output and cause
intermittent jetting. To clean the nozzle:
• Turn o and unplug the unit.
• Disconnect the water supply. Press the trigger 2 or 3 times to release the pressure
trapped in the hose.
• Remove the lance from the trigger gun.
• Turn the nozzle to concentrated mode to activate the internal blades.
• Use the nozzle-cleaning needle provided or any pointy, thin item to clean the nozzle,
e.g., insert an unfolded paper clip into the nozzle hole. Move it inwards and outwards
until all dust and dirt is removed. Fig. 10
• Pour water through the nozzle hole into the nozzle to clean the dirt remains. To do this,
point a lighted garden hose at the nozzle for 30-60 seconds.
6. TROUBLESHOOTING
Problem Possible causes Possible solutions
Smoke comes out of the
device.
Overheating, overloading, or
motor failure.
Switch o the device
immediately and contact
the Technical Support
Service of Cecotec.
There is not enough
pressure.
The water inlet lter is
clogged.
Air is entering from the hose
connections to the pump.
The nozzle or discharge
valve is worn or are not of
the correct size.
Clean the water inlet lter.
Check that the connections
and the locking ring are
tight.
Contact the Technical
Support Service of Cecotec
The pressure washer does
not turn on.
The unit is pressurised.
The plug is not properly
connected, or the socket is
defective.
The extension cord is too
long or short.
The supply voltage is too low.
The thermal safety switch
has tripped.
Press the gun trigger.
Check the plug,
the socket, and fuses.
Remove the extension cord.
Make sure that the mains
voltage matches the
voltage stated on the rating
label of the appliance.
Switch o the device and
allow it to cool down.
08139_HydroBoost 2400 AdvanceClean.indd 7208139_HydroBoost 2400 AdvanceClean.indd 72 18/11/22 9:5718/11/22 9:57