Refrigerant Leak Detector
3
3. SPECIFICATION
Detectable Gases:
R-134a, R-404A, R-407C, R-410A, R-22 etc.
Sensitivity:
H L
R-22,134a 6g/year 30g/year
R-404A,407C,410A 8g/year 40g/year
Alarm Method:
Buzzer, Tricolor LED bar Indicator.
Power Usage:
4 AA size (6V DC) Alkaline Batteries
Snake Tube length: 40cm ( 15.5” )
Dimension / Weight:
173 x 66 x 56 mm ( approximately 400g )
Accessories:
Alkaline batteries ( AA) X 4 pcs
User manual, leak check bottle, carry case.
Battery Life:
Approximately 40 hours normal use.
Auto power OFF:10 minutes
Warm-Up Time: Approximately 90 seconds
Operating Temperature & Humidity:
0 ~40 °C, < 80% RH