OWNER’S MANUAL
FORGE 1500
FORGE 3500
SAVE THESE
INSTRUCTIONS
(p/n 9000578 - REV. A) - 12-DEC-2017
WARNING: If the information in this manual is not followed exactly, a re or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch.
Immediately call your gas supplier. Follow the suppliers instructions.
If you cannot reach your gas supplier, call the re department.
Installation and service must be performed by a qualied installer, service agency or the gas supplier.
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
Tested &
Listed By
US
OUTDOOR COAL FURNACE
0117CB037S

Questions and Answers

  • W
    William PittmanAug 11, 2025
    What to do if my Central Boiler FORGE 1500 Furnace is overheating?
    • I
      ibrooksAug 11, 2025
      If your Central Boiler Furnace is overheating, you can try the following: * Lower the water temperature setpoint. * Ensure the firebox and ash removal doors are properly latched and the seals are in good condition; replace if necessary and adjust if they do not close tightly. * Check for and remove any obstructions. * Verify the pump is operating and water is circulating continuously. * Ensure all valves in the system are open to allow circulation. * Adjust the time between idle pulses of air or decrease the pulse duration (refer to the FireStar operating instructions).
  • A
    Alexa RichardsonSep 4, 2025
    What causes frequent pump trouble in my Central Boiler Furnace?
    • B
      Brian ClarkeSep 5, 2025
      If you're experiencing frequent pump trouble or poor water circulation with your Central Boiler Furnace, consider these factors: * If the pump isn't mounted on the furnace, ensure it's at least four feet lower than the top water level. * If the system was drained or opened, purge it following the Initial Start-up Procedures. * Use softened or filtered water. * If water with high mineral content was used, deposits may have built up. Drain and clean the system with Sludge Conditioner (p/n 166), then refill with Corrosion Inhibitor Plus (p/n 1650) and fresh water.
  • H
    hardingjodyNov 16, 2025
    Why is my Central Boiler FORGE 1500 not operating correctly?
    • S
      Stephen YoderNov 16, 2025
      If your Central Boiler Furnace isn't operating correctly, consider these points: * Add fuel as needed, using properly sized, dry coal. * Clean the air outlets to prevent obstructions. * Check the fan inlet screen and fan for obstructions. * Ensure the airbox cover is properly secured. * If the over/under air actuators aren't working, determine and fix the cause. * Close and properly latch the firebox door, checking the door seal; replace if it's not sealing correctly. * Check the water level and add water if necessary, following the Water Quality and Maintenance guidelines. If the issue persists, contact your Central Boiler dealer. * Determine why the water temperature is too low. * Refer to the FireStar Operating Instructions. * Test for poor draft by loosening the ch...
  • A
    Amanda OdomNov 22, 2025
    What to do if my building is losing temperature with Central Boiler FORGE 1500 Furnace?
    • J
      Jason HartNov 22, 2025
      If your building is losing temperature while using a Central Boiler Furnace, consider the following: * Ensure all necessary valves are open for proper circulation. * Verify the circulator pump is on and the circuit breaker is on and not tripped. If tripped, determine the cause before resetting. * Check that circulation pumps are operating; if not, inspect and attempt to turn the pump shaft. Replace the cartridge or the entire pump if necessary, following supplied instructions. * Try restarting the pump after a 15-second pause. Refer to Initial Start-up Procedures if air needs to be forced from lines. * Evaluate the building's insulation, including ceilings and under radiant flooring. * Confirm the hot supply line is connected correctly and the pump flow direction is accurate; ...
  • D
    David SaundersDec 1, 2025
    Why does the fire in my Central Boiler FORGE 1500 Furnace keep going out?
    • D
      debra97Dec 1, 2025
      If the fire in your Central Boiler Furnace goes out frequently, here are some things to check: * Store coal in a dry place. * Use nut-size coal, avoiding too many fines or pieces larger than stove-size. * Experiment with different loading methods, referring to the Loading Frequency section. * Add small amounts of fuel to re-establish a coal bed before adding a full load. * Adjust the water temperature setpoint higher (see FireStar manual). * Reduce the time between idle pulses of air (see FireStar manual). * Increase the duration of the air pulse (see FireStar manual). * Set the water temperature differential to a smaller value (see FireStar manual). * Maintain approximately three inches of ash for insulation (bituminous coal only). * When burning anthracite, ensure on...