Page 7  Floor Jacks
Troubleshooting
TO PREVENT SERIOUS INJURY:


 If the solutions presented in the Troubleshooting guide do not
solve the problem, have a qualied technician inspect and repair the jack before use.
:






Jack will not
lift at its weight
capacity
Saddle
lowers under
load
Pump stroke
feels spongy
Saddle will not
lift all the way
Handle moves
up when jack
is under load
Oil leaking
from ller plug
X X
Check that Release Valve is closed fully.
Bleed air from the system.
X X X
Valves may be blocked and may not close
fully. To ush the valves:
Lower the Saddle and securely close the 1.
Release Valve.
Manually lift the saddle several inches.2.
Open the release valve and force the 3.
saddle down as quickly as possible.
X
X X
Jack may be low on oil. Check the oil level
and rell if needed.
Jack may require bleeding - see instructions
on page 4.
X
Unit may have too much hydraulic oil inside,
check uid level and adjust if needed.