EasyManua.ls Logo

Cessna 402C - Page 67

Cessna 402C
336 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SECTION 3
EMERGENCY
PROCEOUR~S
(AMPLIFIED
PROCEDURES)
I
FUEL
SYSTEM
EMERGENCY PROCEDURES
ENGINE-DRIVEN
FUEL
PUMP FAILURE
I.
Fuel
Selector -
MAIN
TANK
(Feel
For
Detent).
2.
Auxiliary
Fuel
Pump
-
ON.
3. Mixture -
FULL
RICH.
Adjust fuel flow
to
coincide
with
power
setti
ng.
4.
Cowl
Flap
-
AS
REQUIRED.
5.
As
Soon
as
Practical
-
LAND.
6. Crossfeed
is
unusable
if
the
other
engine
is
operating.
r---------
NOTE
-------....,
If
both
an
engine-driven
fuel
pump
and
an
auxiliary
fuel
pump
fail
on
the
same
side
of
the
airplane,
the
failing
engine cannot
be
supplied with fuel
from
the
opposite
main
tank
since
that
auxiliary
fuel
pump
wil 1
operate
on
the
low
pressure
setting
as long as
the corresponding
engine-driven
fuel
pump
is
opera-
tive.
ELECTRICAL
SYSTEM
EMERGENCY PROCEDURES
ALTERNATOR
FAILURE
(Single)
Indicated
By
Illuminatian
01
1
Failure
Light
1.
Electrical
Load
-
REDUCE.
2.
If
Circuit
Breaker
is
tripped:
a.
Turn
off
affected
alternator.
b. Reset
affected
alternator
circuit
breaker.
c. Turn
on
affected
alternator
switch.
d.
If
circuit
breaker
reopens,
turn
off
alternator.
3.
If
Circuit
Breaker does not
trip:
a.
Select
affected
alternator
on
voltamrooter
and
IOOnitor
output.
b.
If
output
is
normal
and
failure
light
remains on,
disregard
fa;l
i
ndi
ca
ti
on
and
have
indi
ca
tor
checked
after
la
ndi
ng.
c.
If
output
is
insufficient,
turn
off
alternator
and
reduce
electrical
load to one
alternator
capacity.
d.
If
complete
loss
of
alternator
output
occurs,
check
field
fuse
and
replace
if
necessary. Spare fuses
are
located
on
the
left
side
console forward of
the
field
fuses.
e.
If
an
intennittent
light
indication
accompanied
by
voltamrooter
fluctuation
is
observed,
turn
off
affected
alternator
and
reduce load
to
one
alternator
capacity.
f.
Restrict
load
on
remaining
alternator
to
80%
of
the
rated
load.
ALTERNATOR FAILURE
(Dual)
Indicated
By
Illumination
Of
Failure
Light
1.
Electrical
Load
-
REDUCE.
2.
If
Circuit
Breakers
are
tripped:
a.
Turn
off
alternators.
b.
Reset
circuit
breakers.
c.
Turn
on
left
alternator
and
IOOnitor
output
on
voltammeter.
d.
If
alternator
is
charging, leave
it
on. Disregard
failure
light
if
still
illuminated.
e.
If
still
inoperative,
turn
off
left
alternator.
f.
Repeat
steps
c through e
for
right
alternator.
g.
If
circuit
breakers reopen, prepare
to
terminate
flight.
1
November
1979
Do";,,,;
...
n ? _
":I.
tllm
1qA1

Related product manuals