24
Fuse
1,25 AT
Engine
protection switch
Control lamp
Device
button
24 V Power
supply for the
engine part
ENGLISH
11. Fault and error search
When errors occur, the followings point should be observed
1- No function after the connection of the device: NG-3 and NG-4
The automatic security could be interstratis ed. Please disconnect the appliance
switch and try it again after 5 minutes.
Please control the fuse which is on the appliance switch. When the fuse is defect,
exchange it for a new 1,25 At fuse.
1.1- NG5 fault repair
a) Your cutting device can break down because of overheating. Please let your
machine cool down for 5 minutes and try again. When the cutting device doesn’t
function, a specialist or expert must exchange the 0.8 A lock.
3.- Noises in the head part
Check out whether the blade is attached rightfully (the smooth surface should be
visible from above).
Screw the cover bolts tightly, so that they aren’t loose- tting.
• If there are still noises, contact the Devran, Saran or Seymen merchant or the
producer company Ceylan.
2. Fuse replacement
1 2
NG 3 ve NG 4 NG-5
The 0.8 A lock is
located under the
cover/cap and
must be repaired
or exchanged by a
specialist.
The 0.8 A cock is under the
cover.
The On/Off button
is here...