Installation
Operation
Maintenance
Manual
Vertical Stack Units
(Universal Cabinet)
InnKeeper/HomeKeeper
Models: IKV 008-018 IEV 008-012
HKV 016-036 HEV 016-036
www.bulldogheatpump.com
Question and Answer IconNeed help?

Do you have a question about the CGC BULLDOG InnKeeper and is the answer not in the manual?

CGC BULLDOG InnKeeper Specifications

General IconGeneral
BrandCGC
ModelBULLDOG InnKeeper
CategoryHeat Pump
LanguageEnglish

Summary

Unit Installation Procedures

General Installation Checklist

Step-by-step checklist for inspecting the unit, verifying model/voltage, and connecting power supply and grounding.

Electrical Wiring Connections

Main Wiring and Receptacle Specifications

Details on electrical connections to the cabinet, knockouts, and required receptacles matching factory cords.

Control Wiring and Thermostat Settings

Information on control wiring, the absence of a reversing valve, and thermostat settings for heat/cool modes.

Dry Walling and Chassis Installation

Chassis Mounting and Hose Connections

Steps for mounting the chassis, connecting supply/return hoses and condensate line, and performing leak tests.

Unit Operation In-Suite

Cooling and Heating Operation Modes

Description of DX cooling with water-cooled refrigeration and hydronic heating with hot water coil, including compressor behavior.

Standard Heating Operation Stages

Details on the two stages of heating operation, thermostat settings, and how suite temperature affects operation.

Cooling Operation Details

Time Delays and Operational Recommendations

Information on operational time delays and recommendations for thermostat settings during occupancy and absence.

Detailed Operation and Components

Relay Outputs and Digital Inputs

Description of the unit's relay outputs (K1-K6) and digital inputs with LED indicators for various functions.

Analog Inputs and Thermistor Sensors

Explanation of the four analog inputs provided by thermistors (Ta, Tr, Tw, Co) for temperature and level monitoring.

Operational Functions and Start-Up

Fan Operation Logic

How thermostat calls for 'G', 'W', or 'Y' activate fan operation on low or high speed.

Heat Operation Logic

Explanation of how a 'W' call activates the fan at low speed and energizes the heat relay K2.

Cool Start-Up Checks

Sequence of checks for compressor startup, including power ON timer, anti-recycle timer, and pressure switches.

Cool Operation Malfunctions

Malfunctions that cause compressor shutdown during cooling operation, such as head pressure exceeding limits.

Operation Algorithms and Thermostat Compatibility

Operation Algorithm Styles

Description of control algorithms to prevent cycling, including Double Call and Reverse Cycle Call.

Shutdown, Fault Alarms, and Commissioning

Commissioning and Start Up Procedures

Key steps for commissioning and start-up, including system flushing, fluid temperature, and pH balance.

System Parameters and Start-Up

Start Up Record and Operational Expectations

Maintenance Procedures

Diagnosis Table and Troubleshooting