EasyManua.ls Logo

CHAFFOTEAUX PIGMA Gal Evo User Manual

CHAFFOTEAUX PIGMA Gal Evo
73 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Training manual :PIGMA Gal Evo
Training
Handbook
FAMILY: Wall-mounting gas boilers
TYPE: Conventional design
NAME: PIGMA Gal Evo PT IT RDC
TRADE MARK: CHAFFOTEAUX
Issue : 1V0 24.07.2012
Technical support for market

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the CHAFFOTEAUX PIGMA Gal Evo and is the answer not in the manual?

CHAFFOTEAUX PIGMA Gal Evo Specifications

General IconGeneral
BrandCHAFFOTEAUX
ModelPIGMA Gal Evo
CategoryBoiler
LanguageEnglish

Summary

GENERAL INFORMATION

SIZE & DIMENSIONS

Provides dimensions and physical layout of the boiler unit.

OPEN CHAMBER ASSEMBLY VIEW (FF)

Visual diagram showing internal components of the sealed chamber boiler.

CONTROL BOARD

Details the control board, buttons, and display functions for user interaction.

SCREEN

Explains display icons and operating mode indications on the boiler screen.

OPERATION

HEATING MODE

Explains how the boiler functions in heating mode, including component operation.

SANITARY MODE

Details the boiler's operation for domestic hot water production.

SPECIAL FUNCTIONS

FLUE CLEANER FUNCTION

Function for boiler combustion analysis and gas calibration.

COMFORT FUNCTION

Allows user to activate temperature holding in the sanitary water reserve tank.

ANTIFREEZE FUNCTION

Protects the boiler from freezing by activating pump and burner under specific temperature conditions.

WATER FLOW CHECK

Monitors water flow and triggers safety shutdowns based on temperature gradients.

AIR PURGE FUNCTION

Helps purge residual air from the primary circuit after a filling cycle.

SELF ADAPTIVE HEATING RESTART DELAY

Adjusts heating restart delay based on operating conditions or user settings.

HYDRAULIC BLOCK

RIGHT HYDRAULIC BLOCK

Describes the right-side composite hydraulic block with integrated functions.

LEFT HYDRAULIC BLOCK

Details the left-side composite hydraulic module for CH and domestic hot water.

WAY VALVE

Explains the 3-way valve, its motor, and its operation in heating and sanitary modes.

PLATE TYPE HEAT EXCHANGER

Describes the sanitary plate heat exchanger and its role in heat exchange.

PUMP UNIT

Details the pump unit, its types, speeds, and modulation capabilities.

DRAIN PORT & PLUG

Explains how to drain the primary circuit using the drain port and plug.

BY-PASS VALVE

Describes the automatic bypass valve and its function in ensuring minimum flow rate.

PRIMARY HEAT EXCHANGER

Details the primary heat exchanger, its material, and function in heat transfer.

PRESSURE PICK-UPS (FF ONLY)

Explains the function of pressure pick-ups for monitoring primary circuit pressure.

HEATING LINE STRAINER

Describes the heating line filter and instructions for cleaning it.

HEATING EXPANSION VESSEL

Details the heating expansion vessel's technical specifications and capacity.

SANITARY FLOW RATE

Explains the sanitary flow meter operation and its role in initiating ignition sequences.

TEMPERATURE SENSORS

Describes the temperature sensors (NTC1, NTC2) and their resistance values.

GAS LINE

GAS VALVE TYPE SIT SIGMA 845

Details the SIT 845 SIGMA gas valve, its features, and control capabilities.

SOLENOID VALVE ELECTROPNIC CONNECTION DIAGRAM

Provides the electronic connection diagram for the solenoid gas valve.

GAS REGULATIONS

Covers checks and adjustments for gas supply pressure, maximum/minimum power, and ignition.

SUPPLY PRESSURE CHECK

Procedure for checking the gas supply pressure at the inlet.

MAXIMUM SANITARY POWER CHECK

Procedure to check and adjust the maximum power output for sanitary hot water.

MINIMUM POWER CHECK

Procedure to check and adjust the minimum power output for heating and sanitary.

SOFT IGNITION POWER CHECKING

How to check and set the power level for soft ignition.

CLOCKING FOR HEATING RESTART AFTER BURNER FLAME OUT

Setting the delay time between burner shutdown and re-ignition for heating.

CONTROL OF MAXIMUM HEATING POWER

Adjusting the maximum heating power using parameter 230 and 231.

TABE OF GAS

Table detailing gas properties and burner jet specifications for different gas types.

BURNER

Describes the burner assembly, its technology, and nozzle diameters.

FLUE EXHAUST PORTS (SUCTION TYPE MODEL)

Details the flue exhaust ports for combustion analysis and pressure switch testing.

AIR PRESSURE SWITCH (SUCTION CAP TYPE DESIGN)

Explains the air pressure switch function for checking vacuum and extractor operation.

EXTRACTOR (SUCTION CAP TYPE DESIGN)

Details the extractor's technical data and its role in the ventilation system.

POST-VENTILATION

Describes different post-ventilation cycles based on operating conditions and faults.

SPOTT UNIT (MODEL CF)

Explains the SPOTT unit's role in controlling flue stack draft and its thermal contact function.

FLUE EXHAUST / MODEL CF

Details the flue exhaust system for CF models, including anti-return devices and regulations.

SUCTION CUP OUTLET / SUCTION CUPS MODELS / POSSIBLE CONFIGURATIONS

Illustrates exhaust system configurations for coaxial and twin pipe setups.

ELECTRONIC PCBS

MAIN CARD

Describes the GAL2EVO ATM main electronic card and its protective features.

ELECTRONIC WIRING DIAGRAM

Shows the electrical connections and layout of the main electronic PCB.

DIAGRAMME ÉLECTRONIQUE FF BOILER

Provides the electronic diagram for the FF boiler's control board and peripherals.

DIAGRAMME ÉLECTRONIQUE CF BOILER

Provides the electronic diagram for the CF boiler's control board and peripherals.

MENU AND SETTING

USER MENU

Guides the user on navigating and adjusting boiler parameters via the menu system.

COMPLETE MENU

Presents a comprehensive list of all menu parameters, their ranges, and default settings.

MENU 0: NETWORK

Network configuration and status information for the boiler's bus connection.

MENU 2: BOILER PARAMETERS

Settings related to general boiler functions, heating, and hot water.

MENU 4: ZONE 1 PARAMETERS

Configuration parameters for heating zone 1, including setpoints and thermoregulation.

MENU 5: ZONE 2 PARAMETERS

Configuration parameters for heating zone 2, including setpoints and thermoregulation.

MENU 6: ZONE 3 PARAMETERS

Configuration parameters for heating zone 3, including setpoints and thermoregulation.

MENU 8: SERVICE PARAMETER

Access to service parameters, diagnostics, maintenance, and error history.

ERROR CODES

BOILER PROTECTION SYSTEMS

Explains the types of errors, their codes, and reset procedures for boiler malfunctions.

FIRST STARTING AT WORK

PERIODICAL CHECKS

PLATE-TYPE HEAT EXCHANGER FOR SANITARY SYSTEM

Specifies annual checks for the sanitary heat exchanger, focusing on Delta T.

BY PASS & 3-WAY VALVE

Outlines annual visual checks for the bypass and 3-way valve for aspect and property.

HEATING FILTRE

Specifies annual visual checks for the heating filter for aspect and property.

EXPANSION VESSEL

Specifies annual checks for the expansion vessel, including inflating pressure.

CONTROL ASSEMBLY FOR SANITARY WATER FLOWMETER

Details annual checks for the sanitary flowmeter, including start-up flow rate and visual aspect.

IGNITION ELECTRODE & IONIZATION SENSOR

Specifies annual checks for ignition and ionization sensors, including distance and current.

BURNER AND SUPPLY TANK

Outlines annual visual checks for the burner and supply tank for aspect, property, and flame outline.

AIR PRESSURE SWITCH

Details annual checks for the air pressure switch, including DP measurement.

EXTRACTOR

Specifies annual checks for the extractor, focusing on visual aspect, property, and turbine.

EXCHANGER

Outlines annual visual checks for the exchanger for aspect and property.

DONNÉES TECHNIQUES URBIA

PIGMA CF

Provides technical specifications for the PIGMA CF model, including performance and electrical data.

PIGMA FF

Provides technical specifications for the PIGMA FF model, including performance and electrical data.

Related product manuals