#ONTROL "OARD /VERVIEW
3%4 /0%. "UTTON 4HE 3%4 /0%. BUTTON SETS THE /0%. LIMIT 3EE !DJUST ,IMITS SECTION
3%4 #,/3% "UTTON 4HE 3%4 #,/3% BUTTON SETS THE #,/3% LIMIT 3EE !DJUST ,IMITS SECTION
-/6%'!4%"UTTONS4HE -/6% '!4% BUTTONS WILL EITHER OPEN OR CLOSE THE GATE WHEN THE OPERATOR IS IN ,IMIT SETTING MODE 3EE !DJUST ,IMITS SECTION
"!44 &!),
z 7HEN !# POWER IS /&& AND BATTERY VOLTAGE IS CRITICALLY LOW THE GATE WILL LATCH AT A LIMIT UNTIL !# POWER IS RESTORED OR BATTERIES VOLTAGE INCREASES
z /PTION SELECT SWITCH SET TO /0%. FORCES GATE TO AUTOMATICALLY OPEN AND THEN LATCH AT THE /0%. LIMIT UNTIL !# POWER IS RESTORED OR BATTERY VOLTAGE
INCREASES
z /PTION SELECT SWITCH SET TO #,/3% FORCES GATE TO LATCH AT #,/3% LIMIT IF AT #,/3% LIMIT OR ON NEXT #,/3% COMMAND UNTIL !# POWER RESTORED OR BATTERY
VOLTAGE INCREASES
z #ONSTANT PRESSURE ON A HARD COMMAND INPUT OVERRIDES TO OPEN OR CLOSE THE GATE
z #RITICALLY LOW BATTERY
")0!24 $%,!9 3WITCH 4HE ,/#+")0!24 $%,!9 SWITCH IS USED ONLY FOR DUAL GATES 3EE "IPART $ELAY SECTION (#4$#5, /.,9 4HE ")0!24 $%,!9
SWITCH IS USED TO SELECT THE OPENING SPEED
,%!2. "UTTON 4HE ,%!2. BUTTON IS FOR PROGRAMMING REMOTE CONTROLS AND THE NETWORK
4)-%24/#,/3% DIAL 4HE 4)-%24/#,/3% 44# DIAL CAN BE SET TO AUTOMATICALLY CLOSE THE GATE AFTER A SPECIFIED TIME PERIOD 4HE 44# IS FACTORY SET TO
/&& )F THE 44# IS SET TO THE /&& POSITION THEN THE GATE WILL REMAIN OPEN UNTIL THE OPERATOR RECEIVES ANOTHER COMMAND FROM A CONTROL 2OTATE THE 4)-%24/
#,/3% DIAL TO THE DESIRED SETTING 4HE RANGE IS TO  SECONDS SECONDS IS /&& ./4% !NY RADIO COMMAND SINGLE BUTTON CONTROL OR #,/3% COMMAND
ON THE CONTROL BOARD PRIOR TO THE 44# EXPIRING WILL CLOSE THE GATE 4HE 44# IS RESET BY ANY SIGNALS FROM THE OPEN CONTROLS LOOPS CLOSE EDGES AND CLOSE
PHOTOELECTRIC SENSORS )2S
2%6%23!, &/2#% DIAL 4HE 2%6%23!, &/2#% DIAL FINE TUNES THE FORCE 3EE &ORCE !DJUSTMENT SECTION
4%34 "544/.3 4HE 4%34 "544/.3 WILL OPERATE THE GATE /0%. 34/0 AND #,/3%
 34!453 ,%$S 4HE 34!453 ,%$S INDICATE THE STATUS OF THE OPERATOR 3EE 3TATUS ,%$ #HART IN THE 4ROUBLESHOOTING SECTION
 $)!'./34)#3 $ISPLAY 4HE DIAGNOSTICS DISPLAY WILL SHOW THE OPERATOR TYPE FIRMWARE VERSION AND CODES
 "!#+$2)6% 3WITCH 3ET TO -!.5!, WILL ALLOW THE GATE TO BE MANUALLY PUSHED OPEN OR CLOSED IF THERE IS A LOSS OF !# AND BATTERY POWER 3ET TO
3%#52% MAKES THE GATE DIFFICULT TO PUSH OPEN OR CLOSED IF THERE IS A LOSS OF !# AND BATTERY POWER (#4$#5, /.,9 !,7!93 SET TO 3%#52% TO ENABLE
MOTOR BRAKING