en 07/13
Troubleshooting:
Question: Operator will not work anymore without IR sensor.
Solution: Correct. IR sensors are mandatory once connected.
A full logic board reset is required.
E. OPEN, STOP or CLOSE programming of the remote control.
Description of feature:
Each remote control button can be programmed to either OPEN,
STOP or CLOSE the door.
OPEN:
Push yellow round button and UP button simultaneously until the led
goes on. Now push a selcted button on the remote control for OPEN
only and wait for the operator light to flash.
STOP:
Push yellow round button and square button simultaneously until the
led goes on. Now push another selcted button on the remote control
for STOP only and wait for the operator light to flash.
CLOSE:
Push yellow round button and DOWN button simultaneously until the
led goes on. now push a third button on the remote control for
CLOSE only and wait for the operator light to flash.
F. Keyless entry (requires 747REV wireless keypad):
Enter a 4 digit code of your choice to operate the door.
G. Temporary access (requires 747REV wireless keypad):
A temoprary code can be programmed to allow limited acces to the
garage (by time or number of openings).