EasyManua.ls Logo

Chemetron 560 Series User Manual

Chemetron 560 Series
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
____________________________________________________________________________________
Page 1 Allied Healthcare Products, Inc.
Table of Contents
Introduction…………………………………………...1
General Mechanical Principles………………….….2
Materials Of Construction………………….……..…3
Component Parts For Quick Connect
And DISS Outlet Stations……………………..…..3
Inspection, Maintenance And Repair Procedures
(Quick Connect)……………………………….….....4
Inspection, Maintenance And Repair Procedures
(DISS)………………………………………….……..4
Troubleshooting Chart For Quick-Connect Outlet
Stations……………………………………….….....5
Operating Instructions For Chemetron )-Ring Service
Tool……………………………………………..…..7
O-Ring Service Replacement Tool Troubleshooting
Chart…………………………………………...…. 7
Recommendations…………………………...... 8
Additional Product Information…………………...8
Introduction
CHEMETRON MEDICAL GAS OUTLET STATIONS are designed
to provide immediate supply of medical gases and vacuum at such
points of use as hospital operating rooms, emergency rooms,
intensive care and patient rooms, as well as non-hospital based
facilities where a convenient source of medical gases and
additional services are needed.
The medical gases include, but are not limited to, oxygen, nitrus
oxide, compressed air, nitrogen, carbon dioxide, helium and
mixtures of such gases used for medical purposes.
Medical Gas pipeline equipment must be kept in dependable
operating condition at all times, and demand an effective
conscientiously followed program of periodic inspection, cleaning,
maintenance and repair.
For such a program, this manual is a concise, thorough, step-by-
step guide for easy use by responsible maintenance personnel in
hospitals or other installations where Chemetron medical gas
outlet stations are installed.
Read this manual thoroughly, and follow it closely at each
stage of cleaning, maintenance and repair procedures.
It is the responsibility of the user to maintain efficient performance
of Chemetron medical gas outlet stations. Allied Healthcare
Products, Inc. assumes no liability for accidents or other
irregularities arising from failure to observe recommended
maintenance procedures or follow cleaning, maintenance and
repair practices as presented in this manual.
Instructions are applicable to the following series of quick connect
stations; 500 and 560 DISS (Diameter Index Safety System) unit.
Form Number 64-00-2008
(S168-154-001) APRIL 1993
OPERATION, MAINTENANCE & REPAIR MANUAL
MEDICAL GAS
OUTLET STATIONS
500/560 SERIES
Andersen Medical Gas
12 Place Lafifitte
Madisonville, LA 70447
http://www.TheMedicalGas.com
1-866-288-3783
Question and Answer IconNeed help?

Do you have a question about the Chemetron 560 Series and is the answer not in the manual?

Chemetron 560 Series Specifications

General IconGeneral
CategoryMedical Equipment
Series560 Series
ManufacturerChemetron
Gas ServiceOxygen, Medical Air, Nitrous Oxide
Standards ComplianceNFPA 99

Summary

Introduction to Chemetron Medical Gas Outlet Stations

General Mechanical Principles of Operation

Chemetron Outlet Station Design Features

Details the engineered safety keying and design elements for Chemetron medical gas outlets.

Outlet Station Operational Principles

Explains gas pressure, flow conditions, and sealing mechanisms using O-rings.

Materials of Construction and Component Identification

Quick Connect Model Components

Lists materials, parts, and catalog numbers for Quick Connect outlet stations.

DISS Model Components

Lists materials, parts, and catalog numbers for DISS outlet stations.

Inspection and Maintenance Procedures

Quick Connect Outlet Station Maintenance

Step-by-step guide for inspection, disassembly, and repair of quick connect stations.

DISS Outlet Station Maintenance

Step-by-step guide for inspection and maintenance of DISS outlet stations.

Troubleshooting Outlet Station Issues

Quick Connect Station Troubleshooting

Addresses common symptoms like adapter issues, leakage, and reduced flow with corrective actions.

Chemetron O-Ring Service Tool Operation

Valve Body O-Ring Replacement Steps

Detailed instructions for using the O-ring service tool to replace valve body O-rings.

O-Ring Service Tool Troubleshooting Guide

Common problems and solutions when using the O-ring service tool.

Recommendations and Additional Product Info

Modernization Kit Recommendations

Highlights benefits of installing modernization kits for older outlet station series.

Additional Product Information and Parts

Lists related products, repair kits, and manuals for Chemetron medical gas systems.