12
Starting time setting
Dialing Content
Switch No.
SW3
Dialing Illustration
Set Value
1 2 3
ON DP
4
1 2 3
ON DP
4
Starting time 12 minutes
Starting time 3 minutes
1 2
ON DP
1 2
ON DP
1 2
ON DP
1 2
ON DP
1 2
ON DP
3
1 2
ON DP
3
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Address setting
Capacity setting
SW6
SW4+SW5
0-15
16-31
32-47
48-63
8kW
10.5kW
Table 5-2 10.5kw Dialing Table 5-3 14/16 kw Dialing
No.
Current frequency / number of indoor units (standby
display)
Capacity of outdoor unit
Total capacity need of indoor unit
Total capacity needs of corrected host
Operation mode (0-4)
Actual running ability of outdoor unit
Gears of fan (0-7)
T2 / T2 B average temperature
T3 temperature of outdoor condenser
T4 environmental temperature
T5 exhaust temperature
Opening of electronic expansion valve =
spot-check display value × 8
AC transformer current
Input AC voltage
Secondary side current
Secondary side current - (spot-check display × 4)
Number of indoor
Number of working
Last fault protection code (no fault display -)
Control parameters (only for use of development personnel)
Control parameters (only for use of development personnel)
Spot-check Content
1
2
3
4
5
6
7
8
9
10
No. Spot-check Content
12
13
14
15
16
17
18
19
20
21
11
5.4 Outdoor unit spot-check instructions
Table 5-4 Outdoor Unit Spot-check Instructions
Definition of operation mode: 0-Shutdown/air supply; 2-Cooling; 3-Heating; 4-Forced cooling.
Table 5-5 Outdoor Unit Fault Code
E2
E4
E6
E9
E10
H0
H1
Fault Code
Fault Contents
Communication fault between the outdoor unit and the host
Environmental temperature sensor fault
Condenser pipe temperature sensor fault
AC over-voltage / under-voltage protection
EEPROM fault
Communication fault of 0513 and DSP
Communication fault of 0513 and 052 7
E1
Outdoor unit phase-sequence fault
20-minute break at first or 2-minute break later
Remark
Starting time setting
Dialing Content
Switch No.
SW3
Dialing Illustration
Set Value
Starting time 12 minutes
Starting time 3 minutes
1 2
ON DP
1 2
ON DP
1 2
ON DP
1 2
ON DP
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Address setting
Capacity setting
SW6
SW4+SW5
0-15
16-31
32-47
48-63
12kW
14kW
1
ON DP
1
ON DP
16kW
1 2
ON DP
3
1 2
ON DP
3
1 2
ON DP
3
18kW
1 2
ON DP
3