DTSU666 series and DSSU666 series
three phase electronic energy meter
Table 4 The limit value of the active percentage error of meters on imbalanced load
Percentage error limit of various grade
instruments(%)
Table 5 The limit value of the reactive percentage error of meters on imbalanced load
Percentage error limit of various
grade instruments(%)
3.2. Start
Under the power factor of 1.0 and started current, the instrument can be started and continuously
measure (for multiple phase instrument, it will bring balanced load). If the instrument is designed
based on measurement for dual directional energy, then it is applicable for each direction of energy.
Table 6 start current
3.3. Defluction
When adding voltage while there is no current on the current circuit, the test output of the
instrument shall not produce another pulse. When testing, the current circuit shall be opened, and the