Installation
1. Remove the insulated strip, the detector will enter working mode.
2. Use screw to x the probe horizontally on the detection site.
3. Use double-sided adhesive tape to x the transmitter on the place
where the liquid is normally unable to reach, and keep the antenna
upward.
Change Batteries
Open the back case with screwdriver, and replace the batteries with
new ones according to the positive and negative marks.
Specications
Power supply: DC 3 V (AAA 1.5 V LR03 x 2 PCS)
Static current: < 29 uA
Alarm current: < 23 mA
Transmitting distance: < 80 m (in open area)
Radio frequency: 433.92 MHz
Housing material: ABS plastic
Operating condition:
Temperature: -20 °C ~ +55 °C
Relative humidity: < 80% (non-condensing)
Detector dimensions (L x W x H): 54 x 14.5 x 107 mm
Probe dimensions (L x W x H): 35 x 30 x 15 mm