Guidelines for safely moving and lifting the unit, including specific points.
Requirements for selecting a suitable installation location and ensuring proper placement.
Specifies physical dimensions and clearances for units without a water buffer tank.
Physical dimensions and clearances for ILD 2300R-4000R units without a hydraulic module.
Physical dimensions and clearances for ILD 2300R-4000R units with a hydraulic module.
Details physical dimensions and clearances for units equipped with a water buffer tank.
Provides physical specifications, dimensions, and operating weights for LD units.
Provides physical specifications, dimensions, and operating weights for ILD units.
Details electrical specifications for LD units, including voltage, current, and power.
Details electrical specifications for ILD units, including voltage, current, and power.
Details requirements for the unit's power supply, voltage range, and phase imbalance.
Provides guidelines for selecting appropriate cable sections based on current and voltage drop.
Key checks and recommendations for connecting hydraulic circuits to heat exchangers.
Diagrams and component descriptions for hydraulic connections with and without modules.
Specific hydraulic connection details for ILD 2300R-4000R units.
Measures to protect the unit from frost damage, including system draining and antifreeze.
Procedure for setting nominal system water flow rate for units without a hydraulic module.
Procedure for setting nominal flow rate for units with a hydraulic module and fixed-speed pump.
Control of flow rate based on pressure differential for variable-speed pump units.
Control of flow rate based on temperature differential for variable-speed pump units.
Procedure for setting a constant nominal flow rate for the system using variable-speed pumps.
Comprehensive checklist of items to verify before initiating system start-up.
Precautions and steps for the commissioning process, including safety checks.
Key checks for compressors, hydraulics, and refrigerant charge during start-up.
Description of the hydraulic module without variable speed, including pump types and options.
Description of the hydraulic module with variable speed, including pump control and options.
Details on the partial heat recovery option using desuperheaters.
Installation and operational guidance for the heat recovery with desuperheater option.
Information on the total heat recovery option, including physical properties and operating principles.
Details on the operation of the total heat recovery system, including variable water flow control and frost protection.
Advanced maintenance requiring specific skills, tools, and expertise, performed by authorized personnel.