Overview

This document describes the CINCOM CM-028AS Air Compression Leg Massager, a device designed to provide therapeutic massage for the legs.

Function Description

The CINCOM CM-028AS is an air compression leg massager that uses airbags to inflate and deflate, simulating a kneading and stroking massage similar to human hands. This action helps to relax muscles, increase circulation, and relieve pain in the legs. The device offers three massage modes:

  • Sequence Mode: In this mode, the sleeves inflate and deflate from lower to upper.
  • Circulation Mode: In this mode, the sleeves inflate and deflate circularly from lower to upper.
  • Whole Mode: In this mode, the sleeves inflate and deflate simultaneously and wholly.

The device also features three levels of massage strength, allowing users to select the intensity that best suits their needs. An adjustable Velcro strap helps to achieve the right tightness for optimal massage.

Important Technical Specifications

  • Model: CM-028AS
  • Name: Air Compression Leg Massager
  • AC/DC Adapter:
    • Input: 100-240 Volts, AC 50/60 Hz
    • Output: DC 5V 1A
  • Rated Power: 5W
  • Operating Conditions:
    • Temperature: +5°C to 40°C (41°F to 104°F)
    • Humidity: 1% to 90% non-condensing
    • Atmospheric Pressure: 70 kPa to 106 kPa
  • Storage Conditions:
    • Temperature: -20°C to 55°C
    • Humidity: 5% to 90% non-condensing
    • Atmospheric Pressure: 50 kPa to 106 kPa
    • Keep dry and avoid direct sunlight exposure.
  • Timing: 20 minutes (automatic shut-off)

Usage Features

The CM-028AS is designed for ease of use with a simple control panel.

Before Use:

  • Ensure the power adapter is correctly connected and the indicator light is on.
  • Make sure the sleeves are fully charged before first use. The indicator light will be red during charging and green when fully charged.
  • Wear the sleeves on your calves correctly, ensuring a comfortable fit. The sleeves are designed for calves, not for feet.
  • Do not wrap the sleeves too tightly; leave some gap for optimal performance.

Control Panel: The control panel includes:

  • Pause Button: To temporarily stop the massage.
  • Power Button: To turn the device on/off. Press and hold for three seconds to start.
  • Power Adapter Plug: For connecting the power adapter.
  • Mode Button: To switch between the three massage modes (Sequence, Circulation, Whole).
  • Air Pressure Button: To adjust the massage intensity (three levels).

Operating Instructions:

  1. Start the device: Press and hold the "Power Button" for three seconds. It will start in Mode 1 (Sequence Mode) by default, at the lowest intensity.
  2. Select Massage Mode: Press the "Mode Button" to cycle through the three modes (Mode 1, Mode 2, Mode 3). The corresponding indicator light will illuminate.
  3. Adjust Intensity: Press the "Air Pressure Button" to select the desired intensity level (low, medium, high).
  4. Automatic Shut-off: The massager will automatically shut off after 20 minutes. If you wish to continue, you can restart it.
  5. Manual Shut-off: Press and hold the "Power Button" to turn off the device at any time.

Important Safety Precautions:

  • Consult a doctor before use if you have certain medical conditions (e.g., malignant tumors, severe heart diseases, serious peripheral neuropathy, diabetes, skin infections, or are pregnant).
  • Do not use the device on infants, children, or people unable to express discomfort.
  • Do not use any power adapter other than the original one provided.
  • Do not damage, process, excessively bend, pull, or twist the power cord.
  • Do not use the device in high-temperature environments or with wet hands.
  • Do not plug or unplug the power adapter with wet hands.
  • Do not disassemble or repair the machine yourself.
  • If you feel unwell during use, stop immediately and consult a doctor.
  • Do not use in bathrooms or other humid places.
  • Unplug the power adapter when not in use.

Maintenance Features

Cleaning:

  • Always cut off the power when cleaning the machine.
  • Wipe the machine with a soft cloth moistened by soap solution.
  • Do not use gasoline, alcohol, diluent, or other irritating liquids to clean the machine, as this may cause malfunction or discoloration.
  • Toothpicks can be used to remove hair or chippings attached to the Velcros.

Storage:

  • Keep out of reach of children.
  • Do not disassemble the machine.
  • Do not place in high temperature and humidity conditions.
  • Avoid direct sunlight.
  • Avoid needles puncturing the air bags and hoses.
  • Do not place heavy stuff on it.
  • When storing, fold the sleeves into the storage bag.

Disposal:

  • Dispose of the device locally according to regulations when it reaches the end of its lifespan.

Warranty and Contact: CINCOM offers a 2-year warranty and long-term after-sale service. For any product problems during use, customers are encouraged to contact their professional customer service team.

  • E-mail: service@cincomhealth.com
  • Facebook: Cincom
  • Website: www.cincomhealth.com

CINCOM CM-028AS Specifications

General IconGeneral
BrandCINCOM
ModelCM-028AS
CategoryMassager
LanguageEnglish